Cargando…
Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial
INTRODUCTION: The purpose of this study was to test if intravenous (IV) fluids warmed to body temperature are associated with greater patient comfort than room temperature IV fluids in adult emergency department (ED) patients. METHODS: This was a pilot double-blind, crossover, randomized controlled...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Department of Emergency Medicine, University of California, Irvine School of Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3789921/ https://www.ncbi.nlm.nih.gov/pubmed/24106555 http://dx.doi.org/10.5811/westjem.2013.1.13303 |
_version_ | 1782286523806253056 |
---|---|
author | Self, Wesley H. White, Steven J. McNaughton, Candace D. Storrow, Alan B. Slovis, Corey M. Collins, Sean P. |
author_facet | Self, Wesley H. White, Steven J. McNaughton, Candace D. Storrow, Alan B. Slovis, Corey M. Collins, Sean P. |
author_sort | Self, Wesley H. |
collection | PubMed |
description | INTRODUCTION: The purpose of this study was to test if intravenous (IV) fluids warmed to body temperature are associated with greater patient comfort than room temperature IV fluids in adult emergency department (ED) patients. METHODS: This was a pilot double-blind, crossover, randomized controlled trial. Enrolled subjects sequentially received boluses of body temperature (36°C) and room temperature (22 °C) IV fluid, with the order of boluses randomized. Each subject’s level of discomfort was assessed prior to and after each bolus, using a 10 cm visual analog scale (Discomfort VAS), with higher scores indicating greater discomfort. We calculated the change in Discomfort VAS score associated with body temperature IV fluid (ΔVAS(body)) and room temperature IV fluid (ΔVAS(room)) by subtracting the score reported before the bolus from the score reported after that bolus. We compared changes in Discomfort VAS score with body temperature and room temperature IV fluid using the Wilcoxon matched-pairs signed-rank test. RESULTS: Twenty-seven subjects were included. Treatment with body temperature IV fluid was associated with a significant decrease in discomfort (median ΔVAS(body): −0.7 cm; interquartile range (IQR): −4.5 cm to +0.4 cm) compared to room temperature IV fluid (median ΔVAS(room): +1.2 cm; interquartile range: −0.1 cm to + 3.6 cm) (P = 0.001). CONCLUSION: In this small trial of adult ED patients, infusing IV fluids warmed to body temperature was associated with improved comfort compared to standard, room temperature IV fluids. |
format | Online Article Text |
id | pubmed-3789921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Department of Emergency Medicine, University of California, Irvine School of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-37899212013-10-08 Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial Self, Wesley H. White, Steven J. McNaughton, Candace D. Storrow, Alan B. Slovis, Corey M. Collins, Sean P. West J Emerg Med Practice Variability INTRODUCTION: The purpose of this study was to test if intravenous (IV) fluids warmed to body temperature are associated with greater patient comfort than room temperature IV fluids in adult emergency department (ED) patients. METHODS: This was a pilot double-blind, crossover, randomized controlled trial. Enrolled subjects sequentially received boluses of body temperature (36°C) and room temperature (22 °C) IV fluid, with the order of boluses randomized. Each subject’s level of discomfort was assessed prior to and after each bolus, using a 10 cm visual analog scale (Discomfort VAS), with higher scores indicating greater discomfort. We calculated the change in Discomfort VAS score associated with body temperature IV fluid (ΔVAS(body)) and room temperature IV fluid (ΔVAS(room)) by subtracting the score reported before the bolus from the score reported after that bolus. We compared changes in Discomfort VAS score with body temperature and room temperature IV fluid using the Wilcoxon matched-pairs signed-rank test. RESULTS: Twenty-seven subjects were included. Treatment with body temperature IV fluid was associated with a significant decrease in discomfort (median ΔVAS(body): −0.7 cm; interquartile range (IQR): −4.5 cm to +0.4 cm) compared to room temperature IV fluid (median ΔVAS(room): +1.2 cm; interquartile range: −0.1 cm to + 3.6 cm) (P = 0.001). CONCLUSION: In this small trial of adult ED patients, infusing IV fluids warmed to body temperature was associated with improved comfort compared to standard, room temperature IV fluids. Department of Emergency Medicine, University of California, Irvine School of Medicine 2013-09 /pmc/articles/PMC3789921/ /pubmed/24106555 http://dx.doi.org/10.5811/westjem.2013.1.13303 Text en Copyright © 2013 the authors. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Practice Variability Self, Wesley H. White, Steven J. McNaughton, Candace D. Storrow, Alan B. Slovis, Corey M. Collins, Sean P. Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title | Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title_full | Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title_fullStr | Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title_full_unstemmed | Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title_short | Warming Intravenous Fluids for Improved Patient Comfort in the Emergency Department: A Pilot Crossover Randomized Controlled Trial |
title_sort | warming intravenous fluids for improved patient comfort in the emergency department: a pilot crossover randomized controlled trial |
topic | Practice Variability |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3789921/ https://www.ncbi.nlm.nih.gov/pubmed/24106555 http://dx.doi.org/10.5811/westjem.2013.1.13303 |
work_keys_str_mv | AT selfwesleyh warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial AT whitestevenj warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial AT mcnaughtoncandaced warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial AT storrowalanb warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial AT sloviscoreym warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial AT collinsseanp warmingintravenousfluidsforimprovedpatientcomfortintheemergencydepartmentapilotcrossoverrandomizedcontrolledtrial |