Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems
Power line impedance is a very important parameter on the design of power line communications (PLC) modem architecture. Variations on the impedance of the power line affect the communications circuit performance. In order to determine impedance of the power lines, measurements were carried out in Tu...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3791005/ https://www.ncbi.nlm.nih.gov/pubmed/27873974 http://dx.doi.org/10.3390/s8128027 |
_version_ | 1782286686764400640 |
---|---|
author | Cavdar, I. Hakki Karadeniz, Engin |
author_facet | Cavdar, I. Hakki Karadeniz, Engin |
author_sort | Cavdar, I. Hakki |
collection | PubMed |
description | Power line impedance is a very important parameter on the design of power line communications (PLC) modem architecture. Variations on the impedance of the power line affect the communications circuit performance. In order to determine impedance of the power lines, measurements were carried out in Turkey at frequencies ranging from 10 to 170 kHz, (CENELEC A,B,C,D bands). Measurements were conducted in three categories: rural, urban and the industrial power lines. Experimental results are presented in graphical form. The measured impedances were determined as 3-17 ohms, 1-17 ohms, and 1-21 ohms for rural, urban and the industrial lines, respectively. A set of the formulas between impedance and frequency are developed on the power lines using the regression analysis from the obtained empirical data. Signal attenuations on the power lines in the CENELEC band are also measured for rural, urban and industrial regions. Attenuation measurements are repeated for phase-neutral, phase-ground and the neutral-ground conductors. Signal attenuations are found to be 4-30 dB, for different power lines. To establish validity of obtained results for the design of PLC systems, the results are compared with previous investigations. The effects of some household appliances such as TV, PC, UPS, lighting and cooling systems on the impedances and the attenuations for power line communications systems are observed. Some suggestions and proposals are presented for PLC modem designers. |
format | Online Article Text |
id | pubmed-3791005 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-37910052013-10-18 Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems Cavdar, I. Hakki Karadeniz, Engin Sensors (Basel) Article Power line impedance is a very important parameter on the design of power line communications (PLC) modem architecture. Variations on the impedance of the power line affect the communications circuit performance. In order to determine impedance of the power lines, measurements were carried out in Turkey at frequencies ranging from 10 to 170 kHz, (CENELEC A,B,C,D bands). Measurements were conducted in three categories: rural, urban and the industrial power lines. Experimental results are presented in graphical form. The measured impedances were determined as 3-17 ohms, 1-17 ohms, and 1-21 ohms for rural, urban and the industrial lines, respectively. A set of the formulas between impedance and frequency are developed on the power lines using the regression analysis from the obtained empirical data. Signal attenuations on the power lines in the CENELEC band are also measured for rural, urban and industrial regions. Attenuation measurements are repeated for phase-neutral, phase-ground and the neutral-ground conductors. Signal attenuations are found to be 4-30 dB, for different power lines. To establish validity of obtained results for the design of PLC systems, the results are compared with previous investigations. The effects of some household appliances such as TV, PC, UPS, lighting and cooling systems on the impedances and the attenuations for power line communications systems are observed. Some suggestions and proposals are presented for PLC modem designers. Molecular Diversity Preservation International (MDPI) 2008-12-08 /pmc/articles/PMC3791005/ /pubmed/27873974 http://dx.doi.org/10.3390/s8128027 Text en © 2008 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the CreativeCommons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Cavdar, I. Hakki Karadeniz, Engin Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title | Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title_full | Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title_fullStr | Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title_full_unstemmed | Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title_short | Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems |
title_sort | measurements of impedance and attenuation at cenelec bands for power line communications systems |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3791005/ https://www.ncbi.nlm.nih.gov/pubmed/27873974 http://dx.doi.org/10.3390/s8128027 |
work_keys_str_mv | AT cavdarihakki measurementsofimpedanceandattenuationatcenelecbandsforpowerlinecommunicationssystems AT karadenizengin measurementsofimpedanceandattenuationatcenelecbandsforpowerlinecommunicationssystems |