Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography

OBJECTIVES: (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phanto...

Descripción completa

Detalles Bibliográficos
Autores principales: Oguma, Tsuyoshi, Hirai, Toyohiro, Niimi, Akio, Matsumoto, Hisako, Muro, Shigeo, Shigematsu, Michio, Nishimura, Takashi, Kubo, Yoshiro, Mishima, Michiaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3792973/
https://www.ncbi.nlm.nih.gov/pubmed/24116105
http://dx.doi.org/10.1371/journal.pone.0076381
_version_ 1782286912003768320
author Oguma, Tsuyoshi
Hirai, Toyohiro
Niimi, Akio
Matsumoto, Hisako
Muro, Shigeo
Shigematsu, Michio
Nishimura, Takashi
Kubo, Yoshiro
Mishima, Michiaki
author_facet Oguma, Tsuyoshi
Hirai, Toyohiro
Niimi, Akio
Matsumoto, Hisako
Muro, Shigeo
Shigematsu, Michio
Nishimura, Takashi
Kubo, Yoshiro
Mishima, Michiaki
author_sort Oguma, Tsuyoshi
collection PubMed
description OBJECTIVES: (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai), and the wall area percentage (WA%). To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. RESULTS: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001), and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. CONCLUSIONS: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner.
format Online
Article
Text
id pubmed-3792973
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37929732013-10-10 Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography Oguma, Tsuyoshi Hirai, Toyohiro Niimi, Akio Matsumoto, Hisako Muro, Shigeo Shigematsu, Michio Nishimura, Takashi Kubo, Yoshiro Mishima, Michiaki PLoS One Research Article OBJECTIVES: (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai), and the wall area percentage (WA%). To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. RESULTS: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001), and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. CONCLUSIONS: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner. Public Library of Science 2013-10-08 /pmc/articles/PMC3792973/ /pubmed/24116105 http://dx.doi.org/10.1371/journal.pone.0076381 Text en © 2013 Oguma et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Oguma, Tsuyoshi
Hirai, Toyohiro
Niimi, Akio
Matsumoto, Hisako
Muro, Shigeo
Shigematsu, Michio
Nishimura, Takashi
Kubo, Yoshiro
Mishima, Michiaki
Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title_full Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title_fullStr Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title_full_unstemmed Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title_short Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography
title_sort limitations of airway dimension measurement on images obtained using multi-detector row computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3792973/
https://www.ncbi.nlm.nih.gov/pubmed/24116105
http://dx.doi.org/10.1371/journal.pone.0076381
work_keys_str_mv AT ogumatsuyoshi limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT hiraitoyohiro limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT niimiakio limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT matsumotohisako limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT muroshigeo limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT shigematsumichio limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT nishimuratakashi limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT kuboyoshiro limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography
AT mishimamichiaki limitationsofairwaydimensionmeasurementonimagesobtainedusingmultidetectorrowcomputedtomography