Cargando…
Removable molar power arm
Attachment of force elements from the gingival hook of maxillary molar tubes during the retraction of the anterior teeth is very common in orthodontic practice. As the line of force passes below the center of resistance (CR) of molar, it results its mesial tipping and also anchorage loss. To overcom...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3793558/ https://www.ncbi.nlm.nih.gov/pubmed/24124303 http://dx.doi.org/10.4103/0976-237X.118341 |
_version_ | 1782287074496348160 |
---|---|
author | Verma, Raj Kumar Jena, Ashok Kumar Singh, Satinder Pal Utreja, Ashok Kuamr |
author_facet | Verma, Raj Kumar Jena, Ashok Kumar Singh, Satinder Pal Utreja, Ashok Kuamr |
author_sort | Verma, Raj Kumar |
collection | PubMed |
description | Attachment of force elements from the gingival hook of maxillary molar tubes during the retraction of the anterior teeth is very common in orthodontic practice. As the line of force passes below the center of resistance (CR) of molar, it results its mesial tipping and also anchorage loss. To overcome this problem, the line of force should pass along the CR of molar. This article highlights a method to overcome this problem by attaching a removable power arm to the headgear tube of molar tube during the retraction of the anterior teeth. |
format | Online Article Text |
id | pubmed-3793558 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-37935582013-10-11 Removable molar power arm Verma, Raj Kumar Jena, Ashok Kumar Singh, Satinder Pal Utreja, Ashok Kuamr Contemp Clin Dent Case Report Attachment of force elements from the gingival hook of maxillary molar tubes during the retraction of the anterior teeth is very common in orthodontic practice. As the line of force passes below the center of resistance (CR) of molar, it results its mesial tipping and also anchorage loss. To overcome this problem, the line of force should pass along the CR of molar. This article highlights a method to overcome this problem by attaching a removable power arm to the headgear tube of molar tube during the retraction of the anterior teeth. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3793558/ /pubmed/24124303 http://dx.doi.org/10.4103/0976-237X.118341 Text en Copyright: © Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Verma, Raj Kumar Jena, Ashok Kumar Singh, Satinder Pal Utreja, Ashok Kuamr Removable molar power arm |
title | Removable molar power arm |
title_full | Removable molar power arm |
title_fullStr | Removable molar power arm |
title_full_unstemmed | Removable molar power arm |
title_short | Removable molar power arm |
title_sort | removable molar power arm |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3793558/ https://www.ncbi.nlm.nih.gov/pubmed/24124303 http://dx.doi.org/10.4103/0976-237X.118341 |
work_keys_str_mv | AT vermarajkumar removablemolarpowerarm AT jenaashokkumar removablemolarpowerarm AT singhsatinderpal removablemolarpowerarm AT utrejaashokkuamr removablemolarpowerarm |