Cargando…
U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source
A new type of U-shape anti-cathode X-ray generator in which the inner surface of a cylindrical target is irradiated by an electron beam has been made by modifying a conventional rotating anti-cathode X-ray generator whose brightness in the catalog is 12 kW mm(−2). The target material (Cu), target ra...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3795538/ https://www.ncbi.nlm.nih.gov/pubmed/24121322 http://dx.doi.org/10.1107/S0909049513022188 |
_version_ | 1782287388304736256 |
---|---|
author | Sakabe, N. Sakabe, K. Ohsawa, S. Sakai, T. Kobayakawa, H. Sugimura, T. Ikeda, M. Tawada, M. Watanabe, N. Sasaki, K. Wakatsuki, M. |
author_facet | Sakabe, N. Sakabe, K. Ohsawa, S. Sakai, T. Kobayakawa, H. Sugimura, T. Ikeda, M. Tawada, M. Watanabe, N. Sasaki, K. Wakatsuki, M. |
author_sort | Sakabe, N. |
collection | PubMed |
description | A new type of U-shape anti-cathode X-ray generator in which the inner surface of a cylindrical target is irradiated by an electron beam has been made by modifying a conventional rotating anti-cathode X-ray generator whose brightness in the catalog is 12 kW mm(−2). The target material (Cu), target radius (50 mm) and rotating speed (6000 r.p.m.) were not changed in this modification. A brightness of 52 kW mm(−2) was obtained by this U-shape-type X-ray generator. This means that the brightness of the new type is 4.3 times greater than that of the old unmodified one. Furthermore, the new-type X-ray generator yielded a brightness of 129 kW mm(−2) by adding a carbon coating on the Cu target. This means an overall increase of brightness of ten times. The original generator has the highest brightness in the generators of the same class (having a radius of 50 mm and rotation speed of 6000 r.p.m.). Observations showed that Cu Kα counts at vertical incidence of the electron beam onto the surface of the new target, which is initially optically smooth, decrease as the surface is roughened by a severe thermal stress caused by strong electron beam exposure. Further observation reveals, however, that oblique incidence of the electron beam onto the roughened surface drastically increased the X-ray output and amounts to twice as much as that from a smooth surface at vertical incidence. Thus, at the present stage, an overall increase of brightness has been realised at a level 20 times stronger than that of the original commercially offered X-ray generator that we modified. |
format | Online Article Text |
id | pubmed-3795538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-37955382013-10-15 U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source Sakabe, N. Sakabe, K. Ohsawa, S. Sakai, T. Kobayakawa, H. Sugimura, T. Ikeda, M. Tawada, M. Watanabe, N. Sasaki, K. Wakatsuki, M. J Synchrotron Radiat Diffraction Structural Biology A new type of U-shape anti-cathode X-ray generator in which the inner surface of a cylindrical target is irradiated by an electron beam has been made by modifying a conventional rotating anti-cathode X-ray generator whose brightness in the catalog is 12 kW mm(−2). The target material (Cu), target radius (50 mm) and rotating speed (6000 r.p.m.) were not changed in this modification. A brightness of 52 kW mm(−2) was obtained by this U-shape-type X-ray generator. This means that the brightness of the new type is 4.3 times greater than that of the old unmodified one. Furthermore, the new-type X-ray generator yielded a brightness of 129 kW mm(−2) by adding a carbon coating on the Cu target. This means an overall increase of brightness of ten times. The original generator has the highest brightness in the generators of the same class (having a radius of 50 mm and rotation speed of 6000 r.p.m.). Observations showed that Cu Kα counts at vertical incidence of the electron beam onto the surface of the new target, which is initially optically smooth, decrease as the surface is roughened by a severe thermal stress caused by strong electron beam exposure. Further observation reveals, however, that oblique incidence of the electron beam onto the roughened surface drastically increased the X-ray output and amounts to twice as much as that from a smooth surface at vertical incidence. Thus, at the present stage, an overall increase of brightness has been realised at a level 20 times stronger than that of the original commercially offered X-ray generator that we modified. International Union of Crystallography 2013-11-01 2013-10-02 /pmc/articles/PMC3795538/ /pubmed/24121322 http://dx.doi.org/10.1107/S0909049513022188 Text en © N. Sakabe et al. 2013 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Diffraction Structural Biology Sakabe, N. Sakabe, K. Ohsawa, S. Sakai, T. Kobayakawa, H. Sugimura, T. Ikeda, M. Tawada, M. Watanabe, N. Sasaki, K. Wakatsuki, M. U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title | U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title_full | U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title_fullStr | U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title_full_unstemmed | U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title_short | U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source |
title_sort | u-shape rotating anti-cathode compact x-ray generator: 20 times stronger than the commercially available x-ray source |
topic | Diffraction Structural Biology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3795538/ https://www.ncbi.nlm.nih.gov/pubmed/24121322 http://dx.doi.org/10.1107/S0909049513022188 |
work_keys_str_mv | AT sakaben ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT sakabek ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT ohsawas ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT sakait ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT kobayakawah ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT sugimurat ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT ikedam ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT tawadam ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT watanaben ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT sasakik ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource AT wakatsukim ushaperotatinganticathodecompactxraygenerator20timesstrongerthanthecommerciallyavailablexraysource |