Cargando…

Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A

BL-17A is a macromolecular crystallography beamline dedicated to diffraction experiments conducted using micro-crystals and structure determination studies using a lower energy X-ray beam. In these experiments, highly accurate diffraction intensity measurements are definitively important. Since this...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamada, Yusuke, Chavas, Leonard M. G., Igarashi, Noriyuki, Hiraki, Masahiko, Wakatsuki, Soichi, Matsugaki, Naohiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3795560/
https://www.ncbi.nlm.nih.gov/pubmed/24121344
http://dx.doi.org/10.1107/S0909049513022875
_version_ 1782287393546567680
author Yamada, Yusuke
Chavas, Leonard M. G.
Igarashi, Noriyuki
Hiraki, Masahiko
Wakatsuki, Soichi
Matsugaki, Naohiro
author_facet Yamada, Yusuke
Chavas, Leonard M. G.
Igarashi, Noriyuki
Hiraki, Masahiko
Wakatsuki, Soichi
Matsugaki, Naohiro
author_sort Yamada, Yusuke
collection PubMed
description BL-17A is a macromolecular crystallography beamline dedicated to diffraction experiments conducted using micro-crystals and structure determination studies using a lower energy X-ray beam. In these experiments, highly accurate diffraction intensity measurements are definitively important. Since this beamline was constructed, the beamline apparatus has been improved in several ways to enable the collection of accurate diffraction data. The stability of the beam intensities at the sample position was recently improved by modifying the monochromator. The diffractometer has also been improved. A new detector table was installed to prevent distortions in the diffractometer’s base during the repositioning of the diffractometer detector. A new pinhole system and an on-axis viewing system were installed to improve the X-ray beam profile at the sample position and the centering of tiny crystal samples.
format Online
Article
Text
id pubmed-3795560
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-37955602013-10-15 Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A Yamada, Yusuke Chavas, Leonard M. G. Igarashi, Noriyuki Hiraki, Masahiko Wakatsuki, Soichi Matsugaki, Naohiro J Synchrotron Radiat Diffraction Structural Biology BL-17A is a macromolecular crystallography beamline dedicated to diffraction experiments conducted using micro-crystals and structure determination studies using a lower energy X-ray beam. In these experiments, highly accurate diffraction intensity measurements are definitively important. Since this beamline was constructed, the beamline apparatus has been improved in several ways to enable the collection of accurate diffraction data. The stability of the beam intensities at the sample position was recently improved by modifying the monochromator. The diffractometer has also been improved. A new detector table was installed to prevent distortions in the diffractometer’s base during the repositioning of the diffractometer detector. A new pinhole system and an on-axis viewing system were installed to improve the X-ray beam profile at the sample position and the centering of tiny crystal samples. International Union of Crystallography 2013-11-01 2013-10-08 /pmc/articles/PMC3795560/ /pubmed/24121344 http://dx.doi.org/10.1107/S0909049513022875 Text en © Yusuke Yamada et al. 2013 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Diffraction Structural Biology
Yamada, Yusuke
Chavas, Leonard M. G.
Igarashi, Noriyuki
Hiraki, Masahiko
Wakatsuki, Soichi
Matsugaki, Naohiro
Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title_full Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title_fullStr Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title_full_unstemmed Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title_short Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A
title_sort improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline bl-17a
topic Diffraction Structural Biology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3795560/
https://www.ncbi.nlm.nih.gov/pubmed/24121344
http://dx.doi.org/10.1107/S0909049513022875
work_keys_str_mv AT yamadayusuke improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a
AT chavasleonardmg improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a
AT igarashinoriyuki improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a
AT hirakimasahiko improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a
AT wakatsukisoichi improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a
AT matsugakinaohiro improvementstowardhighlyaccuratediffractionexperimentsatthemacromolecularmicrocrystallographybeamlinebl17a