Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures
BACKGROUND: Some in vitro studies warn combining different metals in orthopedic surgery. The aim of this study is to determine the impact of combining titanium and stainless steel on bone healing and the clinical course of patients undergoing internal fixation of femoral fractures. MATERIALS AND MET...
Autores principales: | El-Zayat, Bilal Farouk, Ruchholtz, Steffen, Efe, Turgay, Paletta, Jürgen, Kreslo, Dimitri, Zettl, Ralph |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3796917/ https://www.ncbi.nlm.nih.gov/pubmed/24133304 http://dx.doi.org/10.4103/0019-5413.118200 |
Ejemplares similares
-
Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
por: El-Zayat, Bilal Farouk, et al.
Publicado: (2014) -
Monofilament Cerclage Wiring Fixation with Locking Plates for Distal Femoral Fracture: Is it Appropriate?
por: Lee, Sung Hyun, et al.
Publicado: (2019) -
Screw head plugs increase the fatigue strength of stainless steel, but not of titanium, locking plates
por: Hung, L-W., et al.
Publicado: (2019) -
Mechanical properties of cobalt-chromium wires compared to stainless steel and β-titanium wires
por: Alobeid, Ahmad, et al.
Publicado: (2014) -
Biomechanical Comparison of Tibial Plateau Leveling Osteotomy Performed With a Novel Titanium Alloy Locking Plate Construct vs. an Established Stainless-Steel Locking Plate Construct
por: Bleakley, Seth, et al.
Publicado: (2021)