Cargando…

Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial

BACKGROUND: Total knee arthroplasty (TKA) can result in major postoperative blood loss which can impact on the recovery and rehabilitation of patients. It also requires expensive transfusions. The purpose of the study was to investigate whether a hemostatic matrix, composed of cross-linked gelatin a...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Francesco, Alexander, Flamini, Stefano, Fiori, Filippo, Mastri, Franco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3796920/
https://www.ncbi.nlm.nih.gov/pubmed/24133307
http://dx.doi.org/10.4103/0019-5413.118203
_version_ 1782287553885372416
author Di Francesco, Alexander
Flamini, Stefano
Fiori, Filippo
Mastri, Franco
author_facet Di Francesco, Alexander
Flamini, Stefano
Fiori, Filippo
Mastri, Franco
author_sort Di Francesco, Alexander
collection PubMed
description BACKGROUND: Total knee arthroplasty (TKA) can result in major postoperative blood loss which can impact on the recovery and rehabilitation of patients. It also requires expensive transfusions. The purpose of the study was to investigate whether a hemostatic matrix, composed of cross-linked gelatin and a thrombin solution, would reduce blood loss in patients following TKA. MATERIALS AND METHODS: This was a prospective, randomized, controlled study (Trial registration: Hospital S. Salvatore L’Aquila ADJ00843) conducted in 93 patients. Criteria for participation were unilateral TKA for osteoarthritis, and a preoperative hemoglobin level >13 g/dL. The outcomes measured were postoperative hemoglobin and hematocrit levels measured at 24h, 72 h, and 7 days. The mean total postoperative blood loss was calculated from drainage volume, patient blood volume, hematocrit, and red blood cell volume. In addition, the drain output within 24 h following surgery and any transfusion requirements were determined. RESULTS: Hemostatic matrix-treated patients (n = 51) showed significant reductions in calculated postoperative blood loss of 32.3% and 28.7% versus control in men and women, respectively (P < 0.01). Postoperative blood loss after 24 h in drain was significantly less with the hemostatic matrix versus control, as were decreases in hemoglobin levels 7 days post-surgery (each P < 0.01). Three patients in the control group required blood transfusion, whereas no blood transfusions were necessary in the hemostatic matrix group. CONCLUSION: The use of a hemostatic matrix provides a safe and effective means to reduce blood loss and blood transfusion requirements in TKA.
format Online
Article
Text
id pubmed-3796920
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37969202013-10-16 Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial Di Francesco, Alexander Flamini, Stefano Fiori, Filippo Mastri, Franco Indian J Orthop Original Article BACKGROUND: Total knee arthroplasty (TKA) can result in major postoperative blood loss which can impact on the recovery and rehabilitation of patients. It also requires expensive transfusions. The purpose of the study was to investigate whether a hemostatic matrix, composed of cross-linked gelatin and a thrombin solution, would reduce blood loss in patients following TKA. MATERIALS AND METHODS: This was a prospective, randomized, controlled study (Trial registration: Hospital S. Salvatore L’Aquila ADJ00843) conducted in 93 patients. Criteria for participation were unilateral TKA for osteoarthritis, and a preoperative hemoglobin level >13 g/dL. The outcomes measured were postoperative hemoglobin and hematocrit levels measured at 24h, 72 h, and 7 days. The mean total postoperative blood loss was calculated from drainage volume, patient blood volume, hematocrit, and red blood cell volume. In addition, the drain output within 24 h following surgery and any transfusion requirements were determined. RESULTS: Hemostatic matrix-treated patients (n = 51) showed significant reductions in calculated postoperative blood loss of 32.3% and 28.7% versus control in men and women, respectively (P < 0.01). Postoperative blood loss after 24 h in drain was significantly less with the hemostatic matrix versus control, as were decreases in hemoglobin levels 7 days post-surgery (each P < 0.01). Three patients in the control group required blood transfusion, whereas no blood transfusions were necessary in the hemostatic matrix group. CONCLUSION: The use of a hemostatic matrix provides a safe and effective means to reduce blood loss and blood transfusion requirements in TKA. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3796920/ /pubmed/24133307 http://dx.doi.org/10.4103/0019-5413.118203 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Di Francesco, Alexander
Flamini, Stefano
Fiori, Filippo
Mastri, Franco
Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title_full Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title_fullStr Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title_full_unstemmed Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title_short Hemostatic matrix effects on blood loss after total knee arthroplasty: A randomized controlled trial
title_sort hemostatic matrix effects on blood loss after total knee arthroplasty: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3796920/
https://www.ncbi.nlm.nih.gov/pubmed/24133307
http://dx.doi.org/10.4103/0019-5413.118203
work_keys_str_mv AT difrancescoalexander hemostaticmatrixeffectsonbloodlossaftertotalkneearthroplastyarandomizedcontrolledtrial
AT flaministefano hemostaticmatrixeffectsonbloodlossaftertotalkneearthroplastyarandomizedcontrolledtrial
AT fiorifilippo hemostaticmatrixeffectsonbloodlossaftertotalkneearthroplastyarandomizedcontrolledtrial
AT mastrifranco hemostaticmatrixeffectsonbloodlossaftertotalkneearthroplastyarandomizedcontrolledtrial