Cargando…

Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis

BACKGROUND: To systematically evaluate the visual performance of aspheric AcrySof IQ and spherical AcrySof Natural intraocular lens (IOL) after cataract surgery. METHODOLOGY/PRINCIPAL FINDINGS: Potential randomized controlled trials (RCTs) that involved implanting AcrySof IQ and AcrySof Natural were...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Jianping, Zhao, Jiangyue, Ma, Liwei, Liu, Guangcong, Wu, Di, Zhang, Jinsong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3799620/
https://www.ncbi.nlm.nih.gov/pubmed/24205001
http://dx.doi.org/10.1371/journal.pone.0077860
_version_ 1782287902592466944
author Liu, Jianping
Zhao, Jiangyue
Ma, Liwei
Liu, Guangcong
Wu, Di
Zhang, Jinsong
author_facet Liu, Jianping
Zhao, Jiangyue
Ma, Liwei
Liu, Guangcong
Wu, Di
Zhang, Jinsong
author_sort Liu, Jianping
collection PubMed
description BACKGROUND: To systematically evaluate the visual performance of aspheric AcrySof IQ and spherical AcrySof Natural intraocular lens (IOL) after cataract surgery. METHODOLOGY/PRINCIPAL FINDINGS: Potential randomized controlled trials (RCTs) that involved implanting AcrySof IQ and AcrySof Natural were searched from PubMed, Web of science, EMBASE, Chinese Science and Technology Periodicals Databases and Cochrane Central Register of Controlled Trials. The methodological quality of the studies was assessed by the Jadad method. Standardized mean differences (SMDs) with 95% confidence intervals (CIs) of best-corrected visual acuity (BCVA), contrast sensitivity and spherical aberration were pooled using a random-effects model. Seven studies were identified and analyzed to compare AcrySof IQ (236 eyes) with AcrySof Natural (232 eyes) after phacoemulsification. There was no significant difference in postoperative BCVA between AcrySof IQ and AcrySof Natural (p =0.137) after a follow up of 3 months. For contrast sensitivity, these differences reached statistical significance under photopic conditions at two spatial frequencies (3 cycles per degree (cpd), 6 cpd, 12 cpd, and 18 cpd; p =0.022, p =0.017, p = 0.065, and p=0.191, respectively) and under mesopic conditions at three spatial frequencies (3 cpd, 6 cpd, 12 cpd, and 18 cpd; p =0.007, p =0.033, p =0.030, and p =0.080, respectively). Eyes with AcrySof IQ also had statistically significant less spherical aberration than eyes with AcrySof Natural (p<0.001). Sensitivity analysis showed that the results were relatively stable and reliable. CONCLUSIONS/SIGNIFICANCE: The overall findings indicate that AcrySof IQ with a modified aspheric surface induced significantly less spherical aberration than AcrySof Natural. Contrast sensitivity in eyes with AcrySof IQ is better than that in eyes with AcrySof Natural, especially under mesopic conditions.
format Online
Article
Text
id pubmed-3799620
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37996202013-11-07 Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis Liu, Jianping Zhao, Jiangyue Ma, Liwei Liu, Guangcong Wu, Di Zhang, Jinsong PLoS One Research Article BACKGROUND: To systematically evaluate the visual performance of aspheric AcrySof IQ and spherical AcrySof Natural intraocular lens (IOL) after cataract surgery. METHODOLOGY/PRINCIPAL FINDINGS: Potential randomized controlled trials (RCTs) that involved implanting AcrySof IQ and AcrySof Natural were searched from PubMed, Web of science, EMBASE, Chinese Science and Technology Periodicals Databases and Cochrane Central Register of Controlled Trials. The methodological quality of the studies was assessed by the Jadad method. Standardized mean differences (SMDs) with 95% confidence intervals (CIs) of best-corrected visual acuity (BCVA), contrast sensitivity and spherical aberration were pooled using a random-effects model. Seven studies were identified and analyzed to compare AcrySof IQ (236 eyes) with AcrySof Natural (232 eyes) after phacoemulsification. There was no significant difference in postoperative BCVA between AcrySof IQ and AcrySof Natural (p =0.137) after a follow up of 3 months. For contrast sensitivity, these differences reached statistical significance under photopic conditions at two spatial frequencies (3 cycles per degree (cpd), 6 cpd, 12 cpd, and 18 cpd; p =0.022, p =0.017, p = 0.065, and p=0.191, respectively) and under mesopic conditions at three spatial frequencies (3 cpd, 6 cpd, 12 cpd, and 18 cpd; p =0.007, p =0.033, p =0.030, and p =0.080, respectively). Eyes with AcrySof IQ also had statistically significant less spherical aberration than eyes with AcrySof Natural (p<0.001). Sensitivity analysis showed that the results were relatively stable and reliable. CONCLUSIONS/SIGNIFICANCE: The overall findings indicate that AcrySof IQ with a modified aspheric surface induced significantly less spherical aberration than AcrySof Natural. Contrast sensitivity in eyes with AcrySof IQ is better than that in eyes with AcrySof Natural, especially under mesopic conditions. Public Library of Science 2013-10-18 /pmc/articles/PMC3799620/ /pubmed/24205001 http://dx.doi.org/10.1371/journal.pone.0077860 Text en © 2013 Liu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Liu, Jianping
Zhao, Jiangyue
Ma, Liwei
Liu, Guangcong
Wu, Di
Zhang, Jinsong
Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title_full Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title_fullStr Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title_full_unstemmed Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title_short Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
title_sort contrast sensitivity and spherical aberration in eyes implanted with acrysof iq and acrysof natural intraocular lens: the results of a meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3799620/
https://www.ncbi.nlm.nih.gov/pubmed/24205001
http://dx.doi.org/10.1371/journal.pone.0077860
work_keys_str_mv AT liujianping contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis
AT zhaojiangyue contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis
AT maliwei contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis
AT liuguangcong contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis
AT wudi contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis
AT zhangjinsong contrastsensitivityandsphericalaberrationineyesimplantedwithacrysofiqandacrysofnaturalintraocularlenstheresultsofametaanalysis