Cargando…
A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques
INTRODUCTION: This study compared apical dye penetration using lateral condensation technique (LC) and LC technique with a reciprocal handpiece (mechanical lateral condensation or MLC) as a new method. MATERIALS AND METHODS: Forty-eight human extracted straight canine teeth were used. After crown am...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3800551/ https://www.ncbi.nlm.nih.gov/pubmed/24146675 |
_version_ | 1782287986610667520 |
---|---|
author | Shahriari, Shahriar Jalalzadeh, Seyed Mohsen Moradkhany, Reza Abedi, Hasan |
author_facet | Shahriari, Shahriar Jalalzadeh, Seyed Mohsen Moradkhany, Reza Abedi, Hasan |
author_sort | Shahriari, Shahriar |
collection | PubMed |
description | INTRODUCTION: This study compared apical dye penetration using lateral condensation technique (LC) and LC technique with a reciprocal handpiece (mechanical lateral condensation or MLC) as a new method. MATERIALS AND METHODS: Forty-eight human extracted straight canine teeth were used. After crown amputation, the teeth were randomly divided into four experimental groups of 10 teeth each and two negative and positive control groups of 4 teeth each. The groups were as follows: IA, 10 obturations completed by operator A using the LC technique; Group IB, 10 obturations completed by operator B using the LC technique; Group IIA, 10 obturations completed by operator A using the MLC technique; and Group IIB, 10 obturations completed by operator B using the MLC technique. All roots were placed in 2% methylene blue dye and centrifuged at 3000 rpm for 3 minutes. Following centrifugation, the roots were cut along their long axis and evaluated under a stereomicroscope to measure the depth of dye penetration. RESULTS: A t-test showed that the teeth which were filled by the MLC technique had less dye penetration in comparison with LC technique (P<0.05). CONCLUSION: This in vitro study illustrates that canals obturated with the MLC technique had superior apical seal than canals filled with the LC technique. |
format | Online Article Text |
id | pubmed-3800551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-38005512013-10-21 A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques Shahriari, Shahriar Jalalzadeh, Seyed Mohsen Moradkhany, Reza Abedi, Hasan Iran Endod J Original Article INTRODUCTION: This study compared apical dye penetration using lateral condensation technique (LC) and LC technique with a reciprocal handpiece (mechanical lateral condensation or MLC) as a new method. MATERIALS AND METHODS: Forty-eight human extracted straight canine teeth were used. After crown amputation, the teeth were randomly divided into four experimental groups of 10 teeth each and two negative and positive control groups of 4 teeth each. The groups were as follows: IA, 10 obturations completed by operator A using the LC technique; Group IB, 10 obturations completed by operator B using the LC technique; Group IIA, 10 obturations completed by operator A using the MLC technique; and Group IIB, 10 obturations completed by operator B using the MLC technique. All roots were placed in 2% methylene blue dye and centrifuged at 3000 rpm for 3 minutes. Following centrifugation, the roots were cut along their long axis and evaluated under a stereomicroscope to measure the depth of dye penetration. RESULTS: A t-test showed that the teeth which were filled by the MLC technique had less dye penetration in comparison with LC technique (P<0.05). CONCLUSION: This in vitro study illustrates that canals obturated with the MLC technique had superior apical seal than canals filled with the LC technique. Iranian Center for Endodontic Research 2008-07-10 2008 /pmc/articles/PMC3800551/ /pubmed/24146675 Text en © 2008, Iranian Center for Endodontic Research This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shahriari, Shahriar Jalalzadeh, Seyed Mohsen Moradkhany, Reza Abedi, Hasan A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title | A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title_full | A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title_fullStr | A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title_full_unstemmed | A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title_short | A Comparative Study of Apical Microleakage Using the Conventional Lateral Condensation and Mechanical Lateral Condensation Techniques |
title_sort | comparative study of apical microleakage using the conventional lateral condensation and mechanical lateral condensation techniques |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3800551/ https://www.ncbi.nlm.nih.gov/pubmed/24146675 |
work_keys_str_mv | AT shahriarishahriar acomparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT jalalzadehseyedmohsen acomparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT moradkhanyreza acomparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT abedihasan acomparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT shahriarishahriar comparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT jalalzadehseyedmohsen comparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT moradkhanyreza comparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques AT abedihasan comparativestudyofapicalmicroleakageusingtheconventionallateralcondensationandmechanicallateralcondensationtechniques |