Cargando…
Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain
Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3804469/ https://www.ncbi.nlm.nih.gov/pubmed/24205098 http://dx.doi.org/10.1371/journal.pone.0078078 |
_version_ | 1782288150125608960 |
---|---|
author | Wu, Xiaoping Adriany, Gregor Ugurbil, Kamil Van de Moortele, Pierre-Francois |
author_facet | Wu, Xiaoping Adriany, Gregor Ugurbil, Kamil Van de Moortele, Pierre-Francois |
author_sort | Wu, Xiaoping |
collection | PubMed |
description | Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the proposed method, phantom and in-vivo experiments targeting a uniform excitation in an axial slice were conducted using two-spoke pTX pulses. Even with the pre-emphasis activated, eddy current induced B0 variations with peak-to-peak values greater than 4 kHz were observed on our system during the rapid switches of slice selective gradients. This large B0 variation, when not corrected, resulted in drastically degraded excitation fidelity with the coefficient of variation (CV) of the flip angle calculated for the region of interest being large (∼12% in the phantom and ∼35% in the brain). By comparison, excitation fidelity was effectively restored, and satisfactory flip angle uniformity was achieved when using the proposed method, with the CV value reduced to ∼3% in the phantom and ∼8% in the brain. Additionally, experimental results were in good agreement with the numerical predictions obtained from Bloch simulations. Slice-selective flip angle homogenization in the human brain at 9.4T using 16-channel 3D spoke pTX pulses is achievable despite of large eddy current induced excitation phase errors; correcting for the latter was critical in this success. |
format | Online Article Text |
id | pubmed-3804469 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38044692013-11-07 Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain Wu, Xiaoping Adriany, Gregor Ugurbil, Kamil Van de Moortele, Pierre-Francois PLoS One Research Article Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the proposed method, phantom and in-vivo experiments targeting a uniform excitation in an axial slice were conducted using two-spoke pTX pulses. Even with the pre-emphasis activated, eddy current induced B0 variations with peak-to-peak values greater than 4 kHz were observed on our system during the rapid switches of slice selective gradients. This large B0 variation, when not corrected, resulted in drastically degraded excitation fidelity with the coefficient of variation (CV) of the flip angle calculated for the region of interest being large (∼12% in the phantom and ∼35% in the brain). By comparison, excitation fidelity was effectively restored, and satisfactory flip angle uniformity was achieved when using the proposed method, with the CV value reduced to ∼3% in the phantom and ∼8% in the brain. Additionally, experimental results were in good agreement with the numerical predictions obtained from Bloch simulations. Slice-selective flip angle homogenization in the human brain at 9.4T using 16-channel 3D spoke pTX pulses is achievable despite of large eddy current induced excitation phase errors; correcting for the latter was critical in this success. Public Library of Science 2013-10-21 /pmc/articles/PMC3804469/ /pubmed/24205098 http://dx.doi.org/10.1371/journal.pone.0078078 Text en © 2013 Wu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Wu, Xiaoping Adriany, Gregor Ugurbil, Kamil Van de Moortele, Pierre-Francois Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title | Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title_full | Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title_fullStr | Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title_full_unstemmed | Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title_short | Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain |
title_sort | correcting for strong eddy current induced b0 modulation enables two-spoke rf pulse design with parallel transmission: demonstration at 9.4t in the human brain |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3804469/ https://www.ncbi.nlm.nih.gov/pubmed/24205098 http://dx.doi.org/10.1371/journal.pone.0078078 |
work_keys_str_mv | AT wuxiaoping correctingforstrongeddycurrentinducedb0modulationenablestwospokerfpulsedesignwithparalleltransmissiondemonstrationat94tinthehumanbrain AT adrianygregor correctingforstrongeddycurrentinducedb0modulationenablestwospokerfpulsedesignwithparalleltransmissiondemonstrationat94tinthehumanbrain AT ugurbilkamil correctingforstrongeddycurrentinducedb0modulationenablestwospokerfpulsedesignwithparalleltransmissiondemonstrationat94tinthehumanbrain AT vandemoortelepierrefrancois correctingforstrongeddycurrentinducedb0modulationenablestwospokerfpulsedesignwithparalleltransmissiondemonstrationat94tinthehumanbrain |