Cargando…
Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC
In this article, an interference caused by hemoglobin H (Hb H), during the measurement of hemoglobin A1c (HbA1c) with ion exchange high pressure liquid chromatography (HPLC) method, was presented in blood sample of a 20-year-old male patient. HbA1c measurement was performed with Agilent 1200 HPLC sy...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AVICENA
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3804497/ https://www.ncbi.nlm.nih.gov/pubmed/24167397 http://dx.doi.org/10.5455/aim.2013.21.216-218 |
_version_ | 1782288156558622720 |
---|---|
author | Agilli, Mehmet Yaman, Halil Aydin, Fevzi Nuri Cakir, Erdinc Cayci, Tuncer Kurt, Yasemin Gulcan Akgul, Emin Ozgur Aydin, Ibrahim |
author_facet | Agilli, Mehmet Yaman, Halil Aydin, Fevzi Nuri Cakir, Erdinc Cayci, Tuncer Kurt, Yasemin Gulcan Akgul, Emin Ozgur Aydin, Ibrahim |
author_sort | Agilli, Mehmet |
collection | PubMed |
description | In this article, an interference caused by hemoglobin H (Hb H), during the measurement of hemoglobin A1c (HbA1c) with ion exchange high pressure liquid chromatography (HPLC) method, was presented in blood sample of a 20-year-old male patient. HbA1c measurement was performed with Agilent 1200 HPLC system using a commercial Recipe HbA1c ion-exchange column. Hemoglobin electrophoresis was performed with Interlab G26 agarose electrophoresis automated compact system. HbA1c level was 18.2% and HbA0 level was 81.5% with ion-exchange HPLC method. Patient’s fasting serum glucose was assessed before HbA1c measurement and the result was 165 mg/dL (9.16 mmol/L). On the other hand, the result of HbA0 was 87.9%, Hb H was 10.8% and Hb A2 was 1.3% with electrophoresis. Whole blood test values were within reference ranges except MCV. MCV value was 79.6 fL. It is important to keep in mind that HbA1c level might be considered falsely high with ion-exchange HPLC method because of Hb H containing sample. |
format | Online Article Text |
id | pubmed-3804497 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | AVICENA |
record_format | MEDLINE/PubMed |
spelling | pubmed-38044972013-10-28 Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC Agilli, Mehmet Yaman, Halil Aydin, Fevzi Nuri Cakir, Erdinc Cayci, Tuncer Kurt, Yasemin Gulcan Akgul, Emin Ozgur Aydin, Ibrahim Acta Inform Med Case Report In this article, an interference caused by hemoglobin H (Hb H), during the measurement of hemoglobin A1c (HbA1c) with ion exchange high pressure liquid chromatography (HPLC) method, was presented in blood sample of a 20-year-old male patient. HbA1c measurement was performed with Agilent 1200 HPLC system using a commercial Recipe HbA1c ion-exchange column. Hemoglobin electrophoresis was performed with Interlab G26 agarose electrophoresis automated compact system. HbA1c level was 18.2% and HbA0 level was 81.5% with ion-exchange HPLC method. Patient’s fasting serum glucose was assessed before HbA1c measurement and the result was 165 mg/dL (9.16 mmol/L). On the other hand, the result of HbA0 was 87.9%, Hb H was 10.8% and Hb A2 was 1.3% with electrophoresis. Whole blood test values were within reference ranges except MCV. MCV value was 79.6 fL. It is important to keep in mind that HbA1c level might be considered falsely high with ion-exchange HPLC method because of Hb H containing sample. AVICENA 2013-09 2013 /pmc/articles/PMC3804497/ /pubmed/24167397 http://dx.doi.org/10.5455/aim.2013.21.216-218 Text en © 2013 AVICENA http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Agilli, Mehmet Yaman, Halil Aydin, Fevzi Nuri Cakir, Erdinc Cayci, Tuncer Kurt, Yasemin Gulcan Akgul, Emin Ozgur Aydin, Ibrahim Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title | Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title_full | Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title_fullStr | Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title_full_unstemmed | Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title_short | Hb H Interference on Measurement Of HbA1c With Ion-Exchange HPLC |
title_sort | hb h interference on measurement of hba1c with ion-exchange hplc |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3804497/ https://www.ncbi.nlm.nih.gov/pubmed/24167397 http://dx.doi.org/10.5455/aim.2013.21.216-218 |
work_keys_str_mv | AT agillimehmet hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT yamanhalil hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT aydinfevzinuri hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT cakirerdinc hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT caycituncer hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT kurtyasemingulcan hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT akguleminozgur hbhinterferenceonmeasurementofhba1cwithionexchangehplc AT aydinibrahim hbhinterferenceonmeasurementofhba1cwithionexchangehplc |