The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients

The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and dopple...

Descripción completa

Detalles Bibliográficos
Autores principales: Bogui, Pascal, Balayssac-Siransy, Edwige, Connes, Philippe, Tuo, Nalourgo, Ouattara, Soualiho, Pichon, Aurélien, Dah, Cyrille Serges
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3805528/
https://www.ncbi.nlm.nih.gov/pubmed/24167637
http://dx.doi.org/10.1371/journal.pone.0079086
_version_ 1782477875588366336
author Bogui, Pascal
Balayssac-Siransy, Edwige
Connes, Philippe
Tuo, Nalourgo
Ouattara, Soualiho
Pichon, Aurélien
Dah, Cyrille Serges
author_facet Bogui, Pascal
Balayssac-Siransy, Edwige
Connes, Philippe
Tuo, Nalourgo
Ouattara, Soualiho
Pichon, Aurélien
Dah, Cyrille Serges
author_sort Bogui, Pascal
collection PubMed
description The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i.e. mainly with sickle cell anemia; n = 32), at rest. While doppler echocardiography was able to detect difference in SVI between the two populations, the Physioflow® failed to detect any difference. Bland & Altman analyses have demonstrated no interchangeability between the two methods to assess CI and SVI in anemic patients and healthy subjects. While doppler echocardiography displayed a good concordance for SVI results with those obtained in the literature for anemic patients, the Physioflow® did not. Finally, in contrast to doppler echocardiography: 1) the CI obtained with the Physioflow® was not correlated with the hemoglobin level and 2) the stroke volume determined by the Physioflow® was highly influenced by body surface area. In conclusion, our findings indicate that the Physioflow® device is inaccurate for the measurement of SVI and CI in patients with chronic anemia and has a poor accuracy for the measurement of these parameters in African healthy subjects.
format Online
Article
Text
id pubmed-3805528
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38055282013-10-28 The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients Bogui, Pascal Balayssac-Siransy, Edwige Connes, Philippe Tuo, Nalourgo Ouattara, Soualiho Pichon, Aurélien Dah, Cyrille Serges PLoS One Research Article The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i.e. mainly with sickle cell anemia; n = 32), at rest. While doppler echocardiography was able to detect difference in SVI between the two populations, the Physioflow® failed to detect any difference. Bland & Altman analyses have demonstrated no interchangeability between the two methods to assess CI and SVI in anemic patients and healthy subjects. While doppler echocardiography displayed a good concordance for SVI results with those obtained in the literature for anemic patients, the Physioflow® did not. Finally, in contrast to doppler echocardiography: 1) the CI obtained with the Physioflow® was not correlated with the hemoglobin level and 2) the stroke volume determined by the Physioflow® was highly influenced by body surface area. In conclusion, our findings indicate that the Physioflow® device is inaccurate for the measurement of SVI and CI in patients with chronic anemia and has a poor accuracy for the measurement of these parameters in African healthy subjects. Public Library of Science 2013-10-22 /pmc/articles/PMC3805528/ /pubmed/24167637 http://dx.doi.org/10.1371/journal.pone.0079086 Text en © 2013 BOGUI et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Bogui, Pascal
Balayssac-Siransy, Edwige
Connes, Philippe
Tuo, Nalourgo
Ouattara, Soualiho
Pichon, Aurélien
Dah, Cyrille Serges
The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title_full The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title_fullStr The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title_full_unstemmed The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title_short The PhysioFlow Thoracic Impedancemeter Is Not Valid for the Measurements of Cardiac Hemodynamic Parameters in Chronic Anemic Patients
title_sort physioflow thoracic impedancemeter is not valid for the measurements of cardiac hemodynamic parameters in chronic anemic patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3805528/
https://www.ncbi.nlm.nih.gov/pubmed/24167637
http://dx.doi.org/10.1371/journal.pone.0079086
work_keys_str_mv AT boguipascal thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT balayssacsiransyedwige thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT connesphilippe thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT tuonalourgo thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT ouattarasoualiho thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT pichonaurelien thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT dahcyrilleserges thephysioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT boguipascal physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT balayssacsiransyedwige physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT connesphilippe physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT tuonalourgo physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT ouattarasoualiho physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT pichonaurelien physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients
AT dahcyrilleserges physioflowthoracicimpedancemeterisnotvalidforthemeasurementsofcardiachemodynamicparametersinchronicanemicpatients