Cargando…
Akreos Adapt AO Intraocular Lens Opacification: A Case Report
A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci’ Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL) cau...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3806673/ https://www.ncbi.nlm.nih.gov/pubmed/24163684 http://dx.doi.org/10.1159/000355414 |
_version_ | 1782288408552407040 |
---|---|
author | Forlini, Matteo Orabona, Giancarlo Dell'Aversana Bratu, Adriana Ionela Rossini, Paolo Cavallini, Gian Maria Forlini, Cesare |
author_facet | Forlini, Matteo Orabona, Giancarlo Dell'Aversana Bratu, Adriana Ionela Rossini, Paolo Cavallini, Gian Maria Forlini, Cesare |
author_sort | Forlini, Matteo |
collection | PubMed |
description | A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci’ Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL) causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL. |
format | Online Article Text |
id | pubmed-3806673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-38066732013-10-25 Akreos Adapt AO Intraocular Lens Opacification: A Case Report Forlini, Matteo Orabona, Giancarlo Dell'Aversana Bratu, Adriana Ionela Rossini, Paolo Cavallini, Gian Maria Forlini, Cesare Case Rep Ophthalmol Published online: September, 2013 A 79-year-old hyperglycemic patient was referred to the ‘Santa Maria delle Croci’ Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL) causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL. S. Karger AG 2013-09-26 /pmc/articles/PMC3806673/ /pubmed/24163684 http://dx.doi.org/10.1159/000355414 Text en Copyright © 2013 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC) (www.karger.com/OA-license), applicable to the online version of the article only. Users may download, print and share this work on the Internet for noncommercial purposes only, provided the original work is properly cited, and a link to the original work on http://www.karger.com and the terms of this license are included in any shared versions. |
spellingShingle | Published online: September, 2013 Forlini, Matteo Orabona, Giancarlo Dell'Aversana Bratu, Adriana Ionela Rossini, Paolo Cavallini, Gian Maria Forlini, Cesare Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title | Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title_full | Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title_fullStr | Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title_full_unstemmed | Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title_short | Akreos Adapt AO Intraocular Lens Opacification: A Case Report |
title_sort | akreos adapt ao intraocular lens opacification: a case report |
topic | Published online: September, 2013 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3806673/ https://www.ncbi.nlm.nih.gov/pubmed/24163684 http://dx.doi.org/10.1159/000355414 |
work_keys_str_mv | AT forlinimatteo akreosadaptaointraocularlensopacificationacasereport AT orabonagiancarlodellaversana akreosadaptaointraocularlensopacificationacasereport AT bratuadrianaionela akreosadaptaointraocularlensopacificationacasereport AT rossinipaolo akreosadaptaointraocularlensopacificationacasereport AT cavallinigianmaria akreosadaptaointraocularlensopacificationacasereport AT forlinicesare akreosadaptaointraocularlensopacificationacasereport |