Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis

OBJECTIVE: To compare by meta-analysis the efficacy and safety of sirolimus-eluting and bare-metal stents in coronary artery disease (CAD) patients with diabetes. METHODS: PubMed, MEDLINE and EMBASE were searched from 1971 to 2012. Data on the efficacy and safety of sirolimus-eluting and bare-metal...

Descripción completa

Detalles Bibliográficos
Autores principales: Qiao, Yanxiang, Bian, Yuan, Yan, Xianliang, Liu, Zhenfang, Chen, Yuguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Clinics Cardive Publishing 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3807685/
https://www.ncbi.nlm.nih.gov/pubmed/24217305
http://dx.doi.org/10.5830/CVJA-2013-062
_version_ 1782288502726066176
author Qiao, Yanxiang
Bian, Yuan
Yan, Xianliang
Liu, Zhenfang
Chen, Yuguo
author_facet Qiao, Yanxiang
Bian, Yuan
Yan, Xianliang
Liu, Zhenfang
Chen, Yuguo
author_sort Qiao, Yanxiang
collection PubMed
description OBJECTIVE: To compare by meta-analysis the efficacy and safety of sirolimus-eluting and bare-metal stents in coronary artery disease (CAD) patients with diabetes. METHODS: PubMed, MEDLINE and EMBASE were searched from 1971 to 2012. Data on the efficacy and safety of sirolimus-eluting and bare-metal stents in patients with diabetes were collected. A meta-analysis was then performed on a total of 1 259 CAD patients with diabetes from six studies. The odds ratio (OR) was used for comparison. Subgroup analysis was performed according to the sample size, year of study, subjects’ geographic area and study method. RESULTS: Compared with those in the bare-metal stent group (BMS), the subjects in the sirolimus-eluting stent (SES) group had a reduced risk for major cardiac events [OR 0.42, 95% confidence interval (CI): 024–0.74, p < 0.01] and target-lesion revascularisation (OR 0.26, 95% CI: 0.11–0.59, p < 0.01). There was no difference for myocardial infarction (OR 0.92, 95% CI: 0.61–1.40, p > 0.05) or mortality (OR 1.19, 95% CI: 0.74–1.92, p > 0.05). Subgroup analysis showed a significant difference for overall risk of major cardiac events between SES and BMS when the sample size was ≤ 90 (OR 0.28, 95% CI: 0.16–0.48, p < 0.01), when it was a randomised control trial (RCT) (OR 0.28, 95% CI: 0.19–0.42, p < 0.01), or when it was performed on European subjects (OR 0.45, 95% CI: 0.27–0.77, p < 0.01). The sensitivity was not different when one study was removed at a time. CONCLUSION: Our study confirmed that SES are safer and more effective than BMS in CAD patients with diabetes, as far as major cardiac events are concerned.
format Online
Article
Text
id pubmed-3807685
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Clinics Cardive Publishing
record_format MEDLINE/PubMed
spelling pubmed-38076852013-10-30 Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis Qiao, Yanxiang Bian, Yuan Yan, Xianliang Liu, Zhenfang Chen, Yuguo Cardiovasc J Afr Cardiovascular Topics OBJECTIVE: To compare by meta-analysis the efficacy and safety of sirolimus-eluting and bare-metal stents in coronary artery disease (CAD) patients with diabetes. METHODS: PubMed, MEDLINE and EMBASE were searched from 1971 to 2012. Data on the efficacy and safety of sirolimus-eluting and bare-metal stents in patients with diabetes were collected. A meta-analysis was then performed on a total of 1 259 CAD patients with diabetes from six studies. The odds ratio (OR) was used for comparison. Subgroup analysis was performed according to the sample size, year of study, subjects’ geographic area and study method. RESULTS: Compared with those in the bare-metal stent group (BMS), the subjects in the sirolimus-eluting stent (SES) group had a reduced risk for major cardiac events [OR 0.42, 95% confidence interval (CI): 024–0.74, p < 0.01] and target-lesion revascularisation (OR 0.26, 95% CI: 0.11–0.59, p < 0.01). There was no difference for myocardial infarction (OR 0.92, 95% CI: 0.61–1.40, p > 0.05) or mortality (OR 1.19, 95% CI: 0.74–1.92, p > 0.05). Subgroup analysis showed a significant difference for overall risk of major cardiac events between SES and BMS when the sample size was ≤ 90 (OR 0.28, 95% CI: 0.16–0.48, p < 0.01), when it was a randomised control trial (RCT) (OR 0.28, 95% CI: 0.19–0.42, p < 0.01), or when it was performed on European subjects (OR 0.45, 95% CI: 0.27–0.77, p < 0.01). The sensitivity was not different when one study was removed at a time. CONCLUSION: Our study confirmed that SES are safer and more effective than BMS in CAD patients with diabetes, as far as major cardiac events are concerned. Clinics Cardive Publishing 2013-10 /pmc/articles/PMC3807685/ /pubmed/24217305 http://dx.doi.org/10.5830/CVJA-2013-062 Text en Copyright © 2010 Clinics Cardive Publishing http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Topics
Qiao, Yanxiang
Bian, Yuan
Yan, Xianliang
Liu, Zhenfang
Chen, Yuguo
Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title_full Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title_fullStr Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title_full_unstemmed Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title_short Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
title_sort efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
topic Cardiovascular Topics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3807685/
https://www.ncbi.nlm.nih.gov/pubmed/24217305
http://dx.doi.org/10.5830/CVJA-2013-062
work_keys_str_mv AT qiaoyanxiang efficacyandsafetyofsirolimuselutingstentsversusbaremetalstentsincoronaryarterydiseasepatientswithdiabetesametaanalysis
AT bianyuan efficacyandsafetyofsirolimuselutingstentsversusbaremetalstentsincoronaryarterydiseasepatientswithdiabetesametaanalysis
AT yanxianliang efficacyandsafetyofsirolimuselutingstentsversusbaremetalstentsincoronaryarterydiseasepatientswithdiabetesametaanalysis
AT liuzhenfang efficacyandsafetyofsirolimuselutingstentsversusbaremetalstentsincoronaryarterydiseasepatientswithdiabetesametaanalysis
AT chenyuguo efficacyandsafetyofsirolimuselutingstentsversusbaremetalstentsincoronaryarterydiseasepatientswithdiabetesametaanalysis