Cargando…

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

Objective: To evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) in the diagnosis of coronary artery stenoses by comparing with conventional coronary angiography (CCA). Methodology: CCA and DSCT were performed in 64 patients with suspected coronary artery disease (CAD) respec...

Descripción completa

Detalles Bibliográficos
Autores principales: Lei, Ziqiao, Gu, Jin, Fu, Qing, Shi, Heshui, Xu, Haibo, Han, Ping, Yu, Jianming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publicaitons 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3809194/
https://www.ncbi.nlm.nih.gov/pubmed/24353518
http://dx.doi.org/10.12669/pjms.291.2645
_version_ 1782288657615421440
author Lei, Ziqiao
Gu, Jin
Fu, Qing
Shi, Heshui
Xu, Haibo
Han, Ping
Yu, Jianming
author_facet Lei, Ziqiao
Gu, Jin
Fu, Qing
Shi, Heshui
Xu, Haibo
Han, Ping
Yu, Jianming
author_sort Lei, Ziqiao
collection PubMed
description Objective: To evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) in the diagnosis of coronary artery stenoses by comparing with conventional coronary angiography (CCA). Methodology: CCA and DSCT were performed in 64 patients with suspected coronary artery disease (CAD) respectively (46 male, 18 female, age from 48 to 82 years old, mean 68.18 years). Various post-processing reconstructions of coronary artery and its branches, such as volumetric imaging, multi-planar reconstruction, curved planar reconstruction, maximum intensity projection were used. The coronary segments, with statistical evaluations combined with its diameter ≥1.5mm were collected to analyze the diagnosis accuracy of DSCT on coronary artery stenoses, with CCA as the gold standard. Results: About 4.14% of coronary artery segments could not be evaluated, while 95.86% were evaluable arteries, the sensitivity, specificity, positive and negative predictive value of DSCT for detecting coronary artery stenoses were, 93.58%, 99.61%, 95.31% and 99.48% respectively. There were no significant differences in the diagnostic accuracy of coronary artery stenoses between DSCT and CCA. Conclusion: DSCT is a reliable tool that is accurately appropriate for patients with CAD, as it has a higher accuracy and specificity, which is valuable in the screening of CAD.
format Online
Article
Text
id pubmed-3809194
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Professional Medical Publicaitons
record_format MEDLINE/PubMed
spelling pubmed-38091942013-12-18 The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses Lei, Ziqiao Gu, Jin Fu, Qing Shi, Heshui Xu, Haibo Han, Ping Yu, Jianming Pak J Med Sci Original Article Objective: To evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) in the diagnosis of coronary artery stenoses by comparing with conventional coronary angiography (CCA). Methodology: CCA and DSCT were performed in 64 patients with suspected coronary artery disease (CAD) respectively (46 male, 18 female, age from 48 to 82 years old, mean 68.18 years). Various post-processing reconstructions of coronary artery and its branches, such as volumetric imaging, multi-planar reconstruction, curved planar reconstruction, maximum intensity projection were used. The coronary segments, with statistical evaluations combined with its diameter ≥1.5mm were collected to analyze the diagnosis accuracy of DSCT on coronary artery stenoses, with CCA as the gold standard. Results: About 4.14% of coronary artery segments could not be evaluated, while 95.86% were evaluable arteries, the sensitivity, specificity, positive and negative predictive value of DSCT for detecting coronary artery stenoses were, 93.58%, 99.61%, 95.31% and 99.48% respectively. There were no significant differences in the diagnostic accuracy of coronary artery stenoses between DSCT and CCA. Conclusion: DSCT is a reliable tool that is accurately appropriate for patients with CAD, as it has a higher accuracy and specificity, which is valuable in the screening of CAD. Professional Medical Publicaitons 2013 /pmc/articles/PMC3809194/ /pubmed/24353518 http://dx.doi.org/10.12669/pjms.291.2645 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lei, Ziqiao
Gu, Jin
Fu, Qing
Shi, Heshui
Xu, Haibo
Han, Ping
Yu, Jianming
The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title_full The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title_fullStr The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title_full_unstemmed The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title_short The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses
title_sort diagnostic evaluation of dual-source ct (dsct) in the diagnosis of coronary artery stenoses
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3809194/
https://www.ncbi.nlm.nih.gov/pubmed/24353518
http://dx.doi.org/10.12669/pjms.291.2645
work_keys_str_mv AT leiziqiao thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT gujin thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT fuqing thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT shiheshui thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT xuhaibo thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT hanping thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT yujianming thediagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT leiziqiao diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT gujin diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT fuqing diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT shiheshui diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT xuhaibo diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT hanping diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses
AT yujianming diagnosticevaluationofdualsourcectdsctinthediagnosisofcoronaryarterystenoses