Cargando…

Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation

Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA)....

Descripción completa

Detalles Bibliográficos
Autores principales: Peirovifar, Ali, Eydi, Mahmood, Mirinejhad, Mir Mousa, Mahmoodpoor, Ata, Mohammadi, Afsaneh, EJ Golzari, Samad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publicaitons 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3809272/
https://www.ncbi.nlm.nih.gov/pubmed/24353586
_version_ 1782288676318871552
author Peirovifar, Ali
Eydi, Mahmood
Mirinejhad, Mir Mousa
Mahmoodpoor, Ata
Mohammadi, Afsaneh
EJ Golzari, Samad
author_facet Peirovifar, Ali
Eydi, Mahmood
Mirinejhad, Mir Mousa
Mahmoodpoor, Ata
Mohammadi, Afsaneh
EJ Golzari, Samad
author_sort Peirovifar, Ali
collection PubMed
description Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO(2) and pulse oximetry. System leakage (>100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. Results: Leakage was observed in two and three cases in ETT and LMA groups respectively (P>0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. Conclusion: If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines.
format Online
Article
Text
id pubmed-3809272
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Professional Medical Publicaitons
record_format MEDLINE/PubMed
spelling pubmed-38092722013-12-18 Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation Peirovifar, Ali Eydi, Mahmood Mirinejhad, Mir Mousa Mahmoodpoor, Ata Mohammadi, Afsaneh EJ Golzari, Samad Pak J Med Sci Original Article Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO(2) and pulse oximetry. System leakage (>100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. Results: Leakage was observed in two and three cases in ETT and LMA groups respectively (P>0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. Conclusion: If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines. Professional Medical Publicaitons 2013-04 /pmc/articles/PMC3809272/ /pubmed/24353586 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Peirovifar, Ali
Eydi, Mahmood
Mirinejhad, Mir Mousa
Mahmoodpoor, Ata
Mohammadi, Afsaneh
EJ Golzari, Samad
Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title_full Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title_fullStr Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title_full_unstemmed Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title_short Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
title_sort comparison of postoperative complication between laryngeal mask airway and endotracheal tube during low-flow anesthesia with controlled ventilation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3809272/
https://www.ncbi.nlm.nih.gov/pubmed/24353586
work_keys_str_mv AT peirovifarali comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation
AT eydimahmood comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation
AT mirinejhadmirmousa comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation
AT mahmoodpoorata comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation
AT mohammadiafsaneh comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation
AT ejgolzarisamad comparisonofpostoperativecomplicationbetweenlaryngealmaskairwayandendotrachealtubeduringlowflowanesthesiawithcontrolledventilation