Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipy...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3810545/ https://www.ncbi.nlm.nih.gov/pubmed/24179685 http://dx.doi.org/10.4168/aair.2013.5.6.383 |
_version_ | 1782288806945226752 |
---|---|
author | Hagau, Natalia Longrois, Dan Petrisor, Cristina |
author_facet | Hagau, Natalia Longrois, Dan Petrisor, Cristina |
author_sort | Hagau, Natalia |
collection | PubMed |
description | PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipyrone. METHODS: From 45 patients with a positive history of an immediate hypersensitivity reaction to dipyrone, we found 20 patients with dipyrone-induced anaphylaxis demonstrating positive skin tests. All selected patients, as well as 10 healthy controls, were tested in vivo and in vitro. BAT was performed using Flow 2CAST technique with three low dipyrone concentrations: 25 µg/mL (c1), 2.5 µg/mL (c2) and 0.25 µg/mL (c3). The threshold for BAT positivity was established using receiver operating characteristics (ROC) curve analysis. RESULTS: Using ROC curve analysis the highest area under curve, 0.79 (0.63-0.95) (P<0.01), was found for c3. When the highest stimulation indexes from the three concentrations for each patient were used, ROC curve analysis revealed an area under curve of 0.81 (0.65-0.96) (P<0.01), sensitivity and specificity were 0.70 and 1 and the optimal threshold value for BAT positivity was 1.71. Thirteen patients had a positive BAT for at least one of the tested dipyrone concentrations. All healthy controls presented negative BAT. CONCLUSIONS: BAT might be a useful technique to diagnose dipyrone allergy, provided all three low dipyrone concentrations are used together. With an assay-specific threshold of 1.71, ROC curve analysis yields 70% sensitivity and 100% specificity. |
format | Online Article Text |
id | pubmed-3810545 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease |
record_format | MEDLINE/PubMed |
spelling | pubmed-38105452013-11-01 Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test Hagau, Natalia Longrois, Dan Petrisor, Cristina Allergy Asthma Immunol Res Original Article PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipyrone. METHODS: From 45 patients with a positive history of an immediate hypersensitivity reaction to dipyrone, we found 20 patients with dipyrone-induced anaphylaxis demonstrating positive skin tests. All selected patients, as well as 10 healthy controls, were tested in vivo and in vitro. BAT was performed using Flow 2CAST technique with three low dipyrone concentrations: 25 µg/mL (c1), 2.5 µg/mL (c2) and 0.25 µg/mL (c3). The threshold for BAT positivity was established using receiver operating characteristics (ROC) curve analysis. RESULTS: Using ROC curve analysis the highest area under curve, 0.79 (0.63-0.95) (P<0.01), was found for c3. When the highest stimulation indexes from the three concentrations for each patient were used, ROC curve analysis revealed an area under curve of 0.81 (0.65-0.96) (P<0.01), sensitivity and specificity were 0.70 and 1 and the optimal threshold value for BAT positivity was 1.71. Thirteen patients had a positive BAT for at least one of the tested dipyrone concentrations. All healthy controls presented negative BAT. CONCLUSIONS: BAT might be a useful technique to diagnose dipyrone allergy, provided all three low dipyrone concentrations are used together. With an assay-specific threshold of 1.71, ROC curve analysis yields 70% sensitivity and 100% specificity. The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease 2013-11 2013-08-07 /pmc/articles/PMC3810545/ /pubmed/24179685 http://dx.doi.org/10.4168/aair.2013.5.6.383 Text en Copyright © 2013 The Korean Academy of Asthma, Allergy and Clinical Immunology • The Korean Academy of Pediatric Allergy and Respiratory Disease http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hagau, Natalia Longrois, Dan Petrisor, Cristina Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title | Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title_full | Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title_fullStr | Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title_full_unstemmed | Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title_short | Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test |
title_sort | threshold for positivity and optimal dipyrone concentration in flow cytometry-assisted basophil activation test |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3810545/ https://www.ncbi.nlm.nih.gov/pubmed/24179685 http://dx.doi.org/10.4168/aair.2013.5.6.383 |
work_keys_str_mv | AT hagaunatalia thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest AT longroisdan thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest AT petrisorcristina thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest |