Cargando…

Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test

PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipy...

Descripción completa

Detalles Bibliográficos
Autores principales: Hagau, Natalia, Longrois, Dan, Petrisor, Cristina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3810545/
https://www.ncbi.nlm.nih.gov/pubmed/24179685
http://dx.doi.org/10.4168/aair.2013.5.6.383
_version_ 1782288806945226752
author Hagau, Natalia
Longrois, Dan
Petrisor, Cristina
author_facet Hagau, Natalia
Longrois, Dan
Petrisor, Cristina
author_sort Hagau, Natalia
collection PubMed
description PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipyrone. METHODS: From 45 patients with a positive history of an immediate hypersensitivity reaction to dipyrone, we found 20 patients with dipyrone-induced anaphylaxis demonstrating positive skin tests. All selected patients, as well as 10 healthy controls, were tested in vivo and in vitro. BAT was performed using Flow 2CAST technique with three low dipyrone concentrations: 25 µg/mL (c1), 2.5 µg/mL (c2) and 0.25 µg/mL (c3). The threshold for BAT positivity was established using receiver operating characteristics (ROC) curve analysis. RESULTS: Using ROC curve analysis the highest area under curve, 0.79 (0.63-0.95) (P<0.01), was found for c3. When the highest stimulation indexes from the three concentrations for each patient were used, ROC curve analysis revealed an area under curve of 0.81 (0.65-0.96) (P<0.01), sensitivity and specificity were 0.70 and 1 and the optimal threshold value for BAT positivity was 1.71. Thirteen patients had a positive BAT for at least one of the tested dipyrone concentrations. All healthy controls presented negative BAT. CONCLUSIONS: BAT might be a useful technique to diagnose dipyrone allergy, provided all three low dipyrone concentrations are used together. With an assay-specific threshold of 1.71, ROC curve analysis yields 70% sensitivity and 100% specificity.
format Online
Article
Text
id pubmed-3810545
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease
record_format MEDLINE/PubMed
spelling pubmed-38105452013-11-01 Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test Hagau, Natalia Longrois, Dan Petrisor, Cristina Allergy Asthma Immunol Res Original Article PURPOSE: Basophil activation occurs both in patients with immediate hypersensitivity reactions to anti-inflammatory drugs and in healthy controls in a dose-dependent manner. Our aims were to define the optimal basophil activation test (BAT) concentration and the threshold for BAT positivity for dipyrone. METHODS: From 45 patients with a positive history of an immediate hypersensitivity reaction to dipyrone, we found 20 patients with dipyrone-induced anaphylaxis demonstrating positive skin tests. All selected patients, as well as 10 healthy controls, were tested in vivo and in vitro. BAT was performed using Flow 2CAST technique with three low dipyrone concentrations: 25 µg/mL (c1), 2.5 µg/mL (c2) and 0.25 µg/mL (c3). The threshold for BAT positivity was established using receiver operating characteristics (ROC) curve analysis. RESULTS: Using ROC curve analysis the highest area under curve, 0.79 (0.63-0.95) (P<0.01), was found for c3. When the highest stimulation indexes from the three concentrations for each patient were used, ROC curve analysis revealed an area under curve of 0.81 (0.65-0.96) (P<0.01), sensitivity and specificity were 0.70 and 1 and the optimal threshold value for BAT positivity was 1.71. Thirteen patients had a positive BAT for at least one of the tested dipyrone concentrations. All healthy controls presented negative BAT. CONCLUSIONS: BAT might be a useful technique to diagnose dipyrone allergy, provided all three low dipyrone concentrations are used together. With an assay-specific threshold of 1.71, ROC curve analysis yields 70% sensitivity and 100% specificity. The Korean Academy of Asthma, Allergy and Clinical Immunology; The Korean Academy of Pediatric Allergy and Respiratory Disease 2013-11 2013-08-07 /pmc/articles/PMC3810545/ /pubmed/24179685 http://dx.doi.org/10.4168/aair.2013.5.6.383 Text en Copyright © 2013 The Korean Academy of Asthma, Allergy and Clinical Immunology • The Korean Academy of Pediatric Allergy and Respiratory Disease http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hagau, Natalia
Longrois, Dan
Petrisor, Cristina
Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title_full Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title_fullStr Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title_full_unstemmed Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title_short Threshold for Positivity and Optimal Dipyrone Concentration in Flow Cytometry-Assisted Basophil Activation Test
title_sort threshold for positivity and optimal dipyrone concentration in flow cytometry-assisted basophil activation test
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3810545/
https://www.ncbi.nlm.nih.gov/pubmed/24179685
http://dx.doi.org/10.4168/aair.2013.5.6.383
work_keys_str_mv AT hagaunatalia thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest
AT longroisdan thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest
AT petrisorcristina thresholdforpositivityandoptimaldipyroneconcentrationinflowcytometryassistedbasophilactivationtest