Cargando…

Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples

BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional inde...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Michael J. J., Phillips, Anthony R. J., Hosking, Alexander W. G., MacDonald, Julia R., Bartlett, Adam S. J. R., Hickey, Anthony J. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812173/
https://www.ncbi.nlm.nih.gov/pubmed/24205366
http://dx.doi.org/10.1371/journal.pone.0079097
_version_ 1782288946571509760
author Chu, Michael J. J.
Phillips, Anthony R. J.
Hosking, Alexander W. G.
MacDonald, Julia R.
Bartlett, Adam S. J. R.
Hickey, Anthony J. R.
author_facet Chu, Michael J. J.
Phillips, Anthony R. J.
Hosking, Alexander W. G.
MacDonald, Julia R.
Bartlett, Adam S. J. R.
Hickey, Anthony J. R.
author_sort Chu, Michael J. J.
collection PubMed
description BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.
format Online
Article
Text
id pubmed-3812173
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38121732013-11-07 Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples Chu, Michael J. J. Phillips, Anthony R. J. Hosking, Alexander W. G. MacDonald, Julia R. Bartlett, Adam S. J. R. Hickey, Anthony J. R. PLoS One Research Article BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function. Public Library of Science 2013-10-29 /pmc/articles/PMC3812173/ /pubmed/24205366 http://dx.doi.org/10.1371/journal.pone.0079097 Text en © 2013 Chu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Chu, Michael J. J.
Phillips, Anthony R. J.
Hosking, Alexander W. G.
MacDonald, Julia R.
Bartlett, Adam S. J. R.
Hickey, Anthony J. R.
Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title_full Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title_fullStr Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title_full_unstemmed Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title_short Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples
title_sort hepatic mitochondrial function analysis using needle liver biopsy samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812173/
https://www.ncbi.nlm.nih.gov/pubmed/24205366
http://dx.doi.org/10.1371/journal.pone.0079097
work_keys_str_mv AT chumichaeljj hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples
AT phillipsanthonyrj hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples
AT hoskingalexanderwg hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples
AT macdonaldjuliar hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples
AT bartlettadamsjr hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples
AT hickeyanthonyjr hepaticmitochondrialfunctionanalysisusingneedleliverbiopsysamples