Cargando…
Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice
The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patie...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812224/ https://www.ncbi.nlm.nih.gov/pubmed/24204834 http://dx.doi.org/10.1371/journal.pone.0077456 |
_version_ | 1782288955539980288 |
---|---|
author | Kwak, Nakwon Choi, Sun Mi Lee, Jinwoo Park, Young Sik Lee, Chang-Hoon Lee, Sang-Min Yoo, Chul-Gyu Kim, Young Whan Han, Sung Koo Yim, Jae-Joon |
author_facet | Kwak, Nakwon Choi, Sun Mi Lee, Jinwoo Park, Young Sik Lee, Chang-Hoon Lee, Sang-Min Yoo, Chul-Gyu Kim, Young Whan Han, Sung Koo Yim, Jae-Joon |
author_sort | Kwak, Nakwon |
collection | PubMed |
description | The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0–1) and 6 (3–7) days, respectively. Median time to treatment after initial evaluation was 7 (4–9) days in patients with Xpert MTB/RIF assay, but was 21 (7–33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT. |
format | Online Article Text |
id | pubmed-3812224 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38122242013-11-07 Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice Kwak, Nakwon Choi, Sun Mi Lee, Jinwoo Park, Young Sik Lee, Chang-Hoon Lee, Sang-Min Yoo, Chul-Gyu Kim, Young Whan Han, Sung Koo Yim, Jae-Joon PLoS One Research Article The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0–1) and 6 (3–7) days, respectively. Median time to treatment after initial evaluation was 7 (4–9) days in patients with Xpert MTB/RIF assay, but was 21 (7–33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT. Public Library of Science 2013-10-29 /pmc/articles/PMC3812224/ /pubmed/24204834 http://dx.doi.org/10.1371/journal.pone.0077456 Text en © 2013 Kwak et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Kwak, Nakwon Choi, Sun Mi Lee, Jinwoo Park, Young Sik Lee, Chang-Hoon Lee, Sang-Min Yoo, Chul-Gyu Kim, Young Whan Han, Sung Koo Yim, Jae-Joon Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title | Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title_full | Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title_fullStr | Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title_full_unstemmed | Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title_short | Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice |
title_sort | diagnostic accuracy and turnaround time of the xpert mtb/rif assay in routine clinical practice |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812224/ https://www.ncbi.nlm.nih.gov/pubmed/24204834 http://dx.doi.org/10.1371/journal.pone.0077456 |
work_keys_str_mv | AT kwaknakwon diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT choisunmi diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT leejinwoo diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT parkyoungsik diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT leechanghoon diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT leesangmin diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT yoochulgyu diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT kimyoungwhan diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT hansungkoo diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice AT yimjaejoon diagnosticaccuracyandturnaroundtimeofthexpertmtbrifassayinroutineclinicalpractice |