Cargando…
Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines
A study of the operator contact force influence on the performance of Articulated Arm Coordinate Measuring Machines (AACMMs) is presented in this paper. After developing a sensor capable of measuring the contact force applied by an operator, a ring gauge has been used to analyse the relationship bet...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812612/ https://www.ncbi.nlm.nih.gov/pubmed/23945737 http://dx.doi.org/10.3390/s130810430 |
_version_ | 1782288987619065856 |
---|---|
author | González-Madruga, Daniel Eduardo Cuesta, González Joaquín Barreiro, García Fernandez-Abia, Ana Isabel |
author_facet | González-Madruga, Daniel Eduardo Cuesta, González Joaquín Barreiro, García Fernandez-Abia, Ana Isabel |
author_sort | González-Madruga, Daniel |
collection | PubMed |
description | A study of the operator contact force influence on the performance of Articulated Arm Coordinate Measuring Machines (AACMMs) is presented in this paper. After developing a sensor capable of measuring the contact force applied by an operator, a ring gauge has been used to analyse the relationship between the contact force and diameter and form errors measured with the AACMM. As a result, contact force has been proved as one of the main factors influencing the AACMM performance. A probe deflection model based on the Finite Element Method (FEM) has been also proposed in order to obtain the AACMM probe deflection caused by contact force. This allows measurement correction by comparing them with reference values, specifically, a ring gauge. Experimental test results show a significant measurement improvement that minimizes diameter error. Finally, an uncertainty evaluation for the contact force sensor and AACMM measurements with and without probe deflection model has been carried out in order to validate the ability of the sensor and the methodology followed. |
format | Online Article Text |
id | pubmed-3812612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-38126122013-10-30 Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines González-Madruga, Daniel Eduardo Cuesta, González Joaquín Barreiro, García Fernandez-Abia, Ana Isabel Sensors (Basel) Article A study of the operator contact force influence on the performance of Articulated Arm Coordinate Measuring Machines (AACMMs) is presented in this paper. After developing a sensor capable of measuring the contact force applied by an operator, a ring gauge has been used to analyse the relationship between the contact force and diameter and form errors measured with the AACMM. As a result, contact force has been proved as one of the main factors influencing the AACMM performance. A probe deflection model based on the Finite Element Method (FEM) has been also proposed in order to obtain the AACMM probe deflection caused by contact force. This allows measurement correction by comparing them with reference values, specifically, a ring gauge. Experimental test results show a significant measurement improvement that minimizes diameter error. Finally, an uncertainty evaluation for the contact force sensor and AACMM measurements with and without probe deflection model has been carried out in order to validate the ability of the sensor and the methodology followed. Molecular Diversity Preservation International (MDPI) 2013-08-13 /pmc/articles/PMC3812612/ /pubmed/23945737 http://dx.doi.org/10.3390/s130810430 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article González-Madruga, Daniel Eduardo Cuesta, González Joaquín Barreiro, García Fernandez-Abia, Ana Isabel Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title | Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title_full | Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title_fullStr | Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title_full_unstemmed | Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title_short | Application of a Force Sensor to Improve the Reliability of Measurement with Articulated Arm Coordinate Measuring Machines |
title_sort | application of a force sensor to improve the reliability of measurement with articulated arm coordinate measuring machines |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3812612/ https://www.ncbi.nlm.nih.gov/pubmed/23945737 http://dx.doi.org/10.3390/s130810430 |
work_keys_str_mv | AT gonzalezmadrugadaniel applicationofaforcesensortoimprovethereliabilityofmeasurementwitharticulatedarmcoordinatemeasuringmachines AT eduardocuestagonzalez applicationofaforcesensortoimprovethereliabilityofmeasurementwitharticulatedarmcoordinatemeasuringmachines AT joaquinbarreirogarcia applicationofaforcesensortoimprovethereliabilityofmeasurementwitharticulatedarmcoordinatemeasuringmachines AT fernandezabiaanaisabel applicationofaforcesensortoimprovethereliabilityofmeasurementwitharticulatedarmcoordinatemeasuringmachines |