Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method
The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3813375/ https://www.ncbi.nlm.nih.gov/pubmed/24250672 |
_version_ | 1782289098672701440 |
---|---|
author | Ghari, Tayebeh Kobarfard, Farzad Mortazavi, Seyed Alireza |
author_facet | Ghari, Tayebeh Kobarfard, Farzad Mortazavi, Seyed Alireza |
author_sort | Ghari, Tayebeh |
collection | PubMed |
description | The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. |
format | Online Article Text |
id | pubmed-3813375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-38133752013-11-18 Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method Ghari, Tayebeh Kobarfard, Farzad Mortazavi, Seyed Alireza Iran J Pharm Res Original Article The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. Shaheed Beheshti University of Medical Sciences 2013 /pmc/articles/PMC3813375/ /pubmed/24250672 Text en © 2013 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ghari, Tayebeh Kobarfard, Farzad Mortazavi, Seyed Alireza Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title | Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title_full | Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title_fullStr | Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title_full_unstemmed | Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title_short | Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method |
title_sort | development of a simple rp-hplc-uv method for determination of azithromycin in bulk and pharmaceutical dosage forms as an alternative to the usp method |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3813375/ https://www.ncbi.nlm.nih.gov/pubmed/24250672 |
work_keys_str_mv | AT gharitayebeh developmentofasimplerphplcuvmethodfordeterminationofazithromycininbulkandpharmaceuticaldosageformsasanalternativetotheuspmethod AT kobarfardfarzad developmentofasimplerphplcuvmethodfordeterminationofazithromycininbulkandpharmaceuticaldosageformsasanalternativetotheuspmethod AT mortazaviseyedalireza developmentofasimplerphplcuvmethodfordeterminationofazithromycininbulkandpharmaceuticaldosageformsasanalternativetotheuspmethod |