PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation

OBJECTIVE: To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established routine setting of MRI-guided laser ablation in the human liver. MATERIALS A...

Descripción completa

Detalles Bibliográficos
Autores principales: Rosenberg, Christian, Kickhefel, Antje, Mensel, Birger, Pickartz, Tilman, Puls, Ralf, Roland, Joerg, Hosten, Norbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3813475/
https://www.ncbi.nlm.nih.gov/pubmed/24205260
http://dx.doi.org/10.1371/journal.pone.0078559
_version_ 1782289107733446656
author Rosenberg, Christian
Kickhefel, Antje
Mensel, Birger
Pickartz, Tilman
Puls, Ralf
Roland, Joerg
Hosten, Norbert
author_facet Rosenberg, Christian
Kickhefel, Antje
Mensel, Birger
Pickartz, Tilman
Puls, Ralf
Roland, Joerg
Hosten, Norbert
author_sort Rosenberg, Christian
collection PubMed
description OBJECTIVE: To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established routine setting of MRI-guided laser ablation in the human liver. MATERIALS AND METHODS: 34 cases of PRFS-guided (GRE) laser ablation were retrospectively matched with 34 cases from an earlier patient population of 73 individuals being monitored through T1 magnitude image evaluation (FLASH 2D). The model-specific real-time estimation of necrotizing thermal impact (above 54 °C zone and T1 signal loss, respectively) was correlated in size with the resulting necrosis as shown by lack of enhancement on the first-day contrast exam (T1). Matched groups were compared using the Mann-Whitney test. RESULTS: Online PRFS guidance was available in 33 of 34 cases. Positive size correlation between calculated impact zone and contrast defect at first day was evident in both groups (p < 0.0004). The predictive error estimating necrosis was median 21 % (range 1 % - 52 %) in the PRFS group and 61 % (range 22 - 84 %) in the T1 magnitude group. Differences in estimating lethal impact were significant (p = 0.004), whereas the real extent of therapy-induced necrosis showed no significant difference (p > 0.28) between the two groups. CONCLUSION: PRFS thermometry is feasible in a clinical setting of thermal hepatic tumor ablation. As an interference-free MR-tool for online therapy monitoring its accuracy to predict tissue necrosis is superior to a competing model of thermally induced alteration of the T1 magnitude signal.
format Online
Article
Text
id pubmed-3813475
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38134752013-11-07 PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation Rosenberg, Christian Kickhefel, Antje Mensel, Birger Pickartz, Tilman Puls, Ralf Roland, Joerg Hosten, Norbert PLoS One Research Article OBJECTIVE: To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established routine setting of MRI-guided laser ablation in the human liver. MATERIALS AND METHODS: 34 cases of PRFS-guided (GRE) laser ablation were retrospectively matched with 34 cases from an earlier patient population of 73 individuals being monitored through T1 magnitude image evaluation (FLASH 2D). The model-specific real-time estimation of necrotizing thermal impact (above 54 °C zone and T1 signal loss, respectively) was correlated in size with the resulting necrosis as shown by lack of enhancement on the first-day contrast exam (T1). Matched groups were compared using the Mann-Whitney test. RESULTS: Online PRFS guidance was available in 33 of 34 cases. Positive size correlation between calculated impact zone and contrast defect at first day was evident in both groups (p < 0.0004). The predictive error estimating necrosis was median 21 % (range 1 % - 52 %) in the PRFS group and 61 % (range 22 - 84 %) in the T1 magnitude group. Differences in estimating lethal impact were significant (p = 0.004), whereas the real extent of therapy-induced necrosis showed no significant difference (p > 0.28) between the two groups. CONCLUSION: PRFS thermometry is feasible in a clinical setting of thermal hepatic tumor ablation. As an interference-free MR-tool for online therapy monitoring its accuracy to predict tissue necrosis is superior to a competing model of thermally induced alteration of the T1 magnitude signal. Public Library of Science 2013-10-24 /pmc/articles/PMC3813475/ /pubmed/24205260 http://dx.doi.org/10.1371/journal.pone.0078559 Text en © 2013 Rosenberg et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Rosenberg, Christian
Kickhefel, Antje
Mensel, Birger
Pickartz, Tilman
Puls, Ralf
Roland, Joerg
Hosten, Norbert
PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title_full PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title_fullStr PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title_full_unstemmed PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title_short PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation
title_sort prfs-based mr thermometry versus an alternative t1 magnitude method – comparative performance predicting thermally induced necrosis in hepatic tumor ablation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3813475/
https://www.ncbi.nlm.nih.gov/pubmed/24205260
http://dx.doi.org/10.1371/journal.pone.0078559
work_keys_str_mv AT rosenbergchristian prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT kickhefelantje prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT menselbirger prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT pickartztilman prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT pulsralf prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT rolandjoerg prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation
AT hostennorbert prfsbasedmrthermometryversusanalternativet1magnitudemethodcomparativeperformancepredictingthermallyinducednecrosisinhepatictumorablation