Cargando…

Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma

BACKGROUND: The aim of the study was to evaluate the efficiency and feasibility of contrast-enhanced ultrasound (CEUS) with Sonovue in assessing of renal cell carcinomas (RCCs) following ultrasound (US)-guided percutaneous microwave ablation (MWA). PATINETS AND METHODS: Seventy-nine patients (60 mal...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xin, Liang, Ping, Yu, Jie, Yu, Xiao-Ling, Liu, Fang-Yi, Cheng, Zhi-Gang, Han, Zhi-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Versita, Warsaw 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3814286/
https://www.ncbi.nlm.nih.gov/pubmed/24294186
http://dx.doi.org/10.2478/raon-2013-0038
_version_ 1782289228892209152
author Li, Xin
Liang, Ping
Yu, Jie
Yu, Xiao-Ling
Liu, Fang-Yi
Cheng, Zhi-Gang
Han, Zhi-Yu
author_facet Li, Xin
Liang, Ping
Yu, Jie
Yu, Xiao-Ling
Liu, Fang-Yi
Cheng, Zhi-Gang
Han, Zhi-Yu
author_sort Li, Xin
collection PubMed
description BACKGROUND: The aim of the study was to evaluate the efficiency and feasibility of contrast-enhanced ultrasound (CEUS) with Sonovue in assessing of renal cell carcinomas (RCCs) following ultrasound (US)-guided percutaneous microwave ablation (MWA). PATINETS AND METHODS: Seventy-nine patients (60 males and 19 females) with 83 lesions (mean size 3.2±1.6 cm) were treated by US-guided percutaneous MWA. The CEUS results of the third day after the ablation were compared with the synchronous contrast-enhanced computed tomography (CT)/magnetic resonance imaging (MRI) results and biopsy pathological results. The follow-up was performed by CEUS and CT/MRI after 1, 3, 6 months and every 6 months subsequently. The combination of clinical follow-up results and CT/MRI imaging findings was the reference standard of CEUS results for evaluating the therapeutic effect. The identification of residual or recurrence tumour was assessed by two blinded radiologists. RESULTS: On the third day after MWA, CEUS showed 68 of 83 lesions (68/83, 81.9%) successfully ablated and 15 of 83 (18.1%) with residual tumours. Among residual tumours, 13 (86.7%) were confirmed by contrast-enhanced CT/MRI findings and biopsy results. The sensitivity, specificity, accuracy, positive and negative predictive value of CEUS evaluating the short-term MWA effectiveness were 100%, 97.1%, 97.6%, 86.7% and 100%, respectively. During the six years follow-up (median 26 months), the CEUS showed recurrence in 7 patients, and six of them achieved consistent results on CEUS and CT/MRI imaging. The sensitivity, specificity, accuracy, positive and negative predictive value for CEUS evaluating long-term MWA effectiveness were 85.7%, 98.7%, 97.6%, 85.7% and 98.7%, respectively. CONCLUSIONS: The post-procedural CEUS demonstrated as an effective and feasible method in evaluating a therapeutic effect of RCCs following MWA.
format Online
Article
Text
id pubmed-3814286
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Versita, Warsaw
record_format MEDLINE/PubMed
spelling pubmed-38142862013-12-01 Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma Li, Xin Liang, Ping Yu, Jie Yu, Xiao-Ling Liu, Fang-Yi Cheng, Zhi-Gang Han, Zhi-Yu Radiol Oncol Research Article BACKGROUND: The aim of the study was to evaluate the efficiency and feasibility of contrast-enhanced ultrasound (CEUS) with Sonovue in assessing of renal cell carcinomas (RCCs) following ultrasound (US)-guided percutaneous microwave ablation (MWA). PATINETS AND METHODS: Seventy-nine patients (60 males and 19 females) with 83 lesions (mean size 3.2±1.6 cm) were treated by US-guided percutaneous MWA. The CEUS results of the third day after the ablation were compared with the synchronous contrast-enhanced computed tomography (CT)/magnetic resonance imaging (MRI) results and biopsy pathological results. The follow-up was performed by CEUS and CT/MRI after 1, 3, 6 months and every 6 months subsequently. The combination of clinical follow-up results and CT/MRI imaging findings was the reference standard of CEUS results for evaluating the therapeutic effect. The identification of residual or recurrence tumour was assessed by two blinded radiologists. RESULTS: On the third day after MWA, CEUS showed 68 of 83 lesions (68/83, 81.9%) successfully ablated and 15 of 83 (18.1%) with residual tumours. Among residual tumours, 13 (86.7%) were confirmed by contrast-enhanced CT/MRI findings and biopsy results. The sensitivity, specificity, accuracy, positive and negative predictive value of CEUS evaluating the short-term MWA effectiveness were 100%, 97.1%, 97.6%, 86.7% and 100%, respectively. During the six years follow-up (median 26 months), the CEUS showed recurrence in 7 patients, and six of them achieved consistent results on CEUS and CT/MRI imaging. The sensitivity, specificity, accuracy, positive and negative predictive value for CEUS evaluating long-term MWA effectiveness were 85.7%, 98.7%, 97.6%, 85.7% and 98.7%, respectively. CONCLUSIONS: The post-procedural CEUS demonstrated as an effective and feasible method in evaluating a therapeutic effect of RCCs following MWA. Versita, Warsaw 2013-10-08 /pmc/articles/PMC3814286/ /pubmed/24294186 http://dx.doi.org/10.2478/raon-2013-0038 Text en Copyright © by Association of Radiology & Oncology http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Research Article
Li, Xin
Liang, Ping
Yu, Jie
Yu, Xiao-Ling
Liu, Fang-Yi
Cheng, Zhi-Gang
Han, Zhi-Yu
Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title_full Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title_fullStr Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title_full_unstemmed Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title_short Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
title_sort role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3814286/
https://www.ncbi.nlm.nih.gov/pubmed/24294186
http://dx.doi.org/10.2478/raon-2013-0038
work_keys_str_mv AT lixin roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT liangping roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT yujie roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT yuxiaoling roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT liufangyi roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT chengzhigang roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma
AT hanzhiyu roleofcontrastenhancedultrasoundinevaluatingtheefficiencyofultrasoundguidedpercutaneousmicrowaveablationinpatientswithrenalcellcarcinoma