Cargando…

An edge-directed interpolation method for fetal spine MR images

BACKGROUND: Fetal spinal magnetic resonance imaging (MRI) is a prenatal routine for proper assessment of fetus development, especially when suspected spinal malformations occur while ultrasound fails to provide details. Limited by hardware, fetal spine MR images suffer from its low resolution. High-...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Shaode, Zhang, Rui, Wu, Shibin, Hu, Jiani, Xie, Yaoqin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819279/
https://www.ncbi.nlm.nih.gov/pubmed/24112777
http://dx.doi.org/10.1186/1475-925X-12-102
_version_ 1782289966217297920
author Yu, Shaode
Zhang, Rui
Wu, Shibin
Hu, Jiani
Xie, Yaoqin
author_facet Yu, Shaode
Zhang, Rui
Wu, Shibin
Hu, Jiani
Xie, Yaoqin
author_sort Yu, Shaode
collection PubMed
description BACKGROUND: Fetal spinal magnetic resonance imaging (MRI) is a prenatal routine for proper assessment of fetus development, especially when suspected spinal malformations occur while ultrasound fails to provide details. Limited by hardware, fetal spine MR images suffer from its low resolution. High-resolution MR images can directly enhance readability and improve diagnosis accuracy. Image interpolation for higher resolution is required in clinical situations, while many methods fail to preserve edge structures. Edge carries heavy structural messages of objects in visual scenes for doctors to detect suspicions, classify malformations and make correct diagnosis. Effective interpolation with well-preserved edge structures is still challenging. METHOD: In this paper, we propose an edge-directed interpolation (EDI) method and apply it on a group of fetal spine MR images to evaluate its feasibility and performance. This method takes edge messages from Canny edge detector to guide further pixel modification. First, low-resolution (LR) images of fetal spine are interpolated into high-resolution (HR) images with targeted factor by bi-linear method. Then edge information from LR and HR images is put into a twofold strategy to sharpen or soften edge structures. Finally a HR image with well-preserved edge structures is generated. The HR images obtained from proposed method are validated and compared with that from other four EDI methods. Performances are evaluated from six metrics, and subjective analysis of visual quality is based on regions of interest (ROI). RESULTS: All these five EDI methods are able to generate HR images with enriched details. From quantitative analysis of six metrics, the proposed method outperforms the other four from signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), structure similarity index (SSIM), feature similarity index (FSIM) and mutual information (MI) with seconds-level time consumptions (TC). Visual analysis of ROI shows that the proposed method maintains better consistency in edge structures with the original images. CONCLUSIONS: The proposed method classifies edge orientations into four categories and well preserves structures. It generates convincing HR images with fine details and is suitable in real-time situations. Iterative curvature-based interpolation (ICBI) method may result in crisper edges, while the other three methods are sensitive to noise and artifacts.
format Online
Article
Text
id pubmed-3819279
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38192792013-11-12 An edge-directed interpolation method for fetal spine MR images Yu, Shaode Zhang, Rui Wu, Shibin Hu, Jiani Xie, Yaoqin Biomed Eng Online Research BACKGROUND: Fetal spinal magnetic resonance imaging (MRI) is a prenatal routine for proper assessment of fetus development, especially when suspected spinal malformations occur while ultrasound fails to provide details. Limited by hardware, fetal spine MR images suffer from its low resolution. High-resolution MR images can directly enhance readability and improve diagnosis accuracy. Image interpolation for higher resolution is required in clinical situations, while many methods fail to preserve edge structures. Edge carries heavy structural messages of objects in visual scenes for doctors to detect suspicions, classify malformations and make correct diagnosis. Effective interpolation with well-preserved edge structures is still challenging. METHOD: In this paper, we propose an edge-directed interpolation (EDI) method and apply it on a group of fetal spine MR images to evaluate its feasibility and performance. This method takes edge messages from Canny edge detector to guide further pixel modification. First, low-resolution (LR) images of fetal spine are interpolated into high-resolution (HR) images with targeted factor by bi-linear method. Then edge information from LR and HR images is put into a twofold strategy to sharpen or soften edge structures. Finally a HR image with well-preserved edge structures is generated. The HR images obtained from proposed method are validated and compared with that from other four EDI methods. Performances are evaluated from six metrics, and subjective analysis of visual quality is based on regions of interest (ROI). RESULTS: All these five EDI methods are able to generate HR images with enriched details. From quantitative analysis of six metrics, the proposed method outperforms the other four from signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), structure similarity index (SSIM), feature similarity index (FSIM) and mutual information (MI) with seconds-level time consumptions (TC). Visual analysis of ROI shows that the proposed method maintains better consistency in edge structures with the original images. CONCLUSIONS: The proposed method classifies edge orientations into four categories and well preserves structures. It generates convincing HR images with fine details and is suitable in real-time situations. Iterative curvature-based interpolation (ICBI) method may result in crisper edges, while the other three methods are sensitive to noise and artifacts. BioMed Central 2013-10-10 /pmc/articles/PMC3819279/ /pubmed/24112777 http://dx.doi.org/10.1186/1475-925X-12-102 Text en Copyright © 2013 Yu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License(http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Yu, Shaode
Zhang, Rui
Wu, Shibin
Hu, Jiani
Xie, Yaoqin
An edge-directed interpolation method for fetal spine MR images
title An edge-directed interpolation method for fetal spine MR images
title_full An edge-directed interpolation method for fetal spine MR images
title_fullStr An edge-directed interpolation method for fetal spine MR images
title_full_unstemmed An edge-directed interpolation method for fetal spine MR images
title_short An edge-directed interpolation method for fetal spine MR images
title_sort edge-directed interpolation method for fetal spine mr images
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819279/
https://www.ncbi.nlm.nih.gov/pubmed/24112777
http://dx.doi.org/10.1186/1475-925X-12-102
work_keys_str_mv AT yushaode anedgedirectedinterpolationmethodforfetalspinemrimages
AT zhangrui anedgedirectedinterpolationmethodforfetalspinemrimages
AT wushibin anedgedirectedinterpolationmethodforfetalspinemrimages
AT hujiani anedgedirectedinterpolationmethodforfetalspinemrimages
AT xieyaoqin anedgedirectedinterpolationmethodforfetalspinemrimages
AT yushaode edgedirectedinterpolationmethodforfetalspinemrimages
AT zhangrui edgedirectedinterpolationmethodforfetalspinemrimages
AT wushibin edgedirectedinterpolationmethodforfetalspinemrimages
AT hujiani edgedirectedinterpolationmethodforfetalspinemrimages
AT xieyaoqin edgedirectedinterpolationmethodforfetalspinemrimages