Cargando…

Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay

BACKGROUND: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Kyunghoon, Park, Hyung-Doo, Kang, Eun-Suk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819441/
https://www.ncbi.nlm.nih.gov/pubmed/24205491
http://dx.doi.org/10.3343/alm.2013.33.6.420
_version_ 1782289992491466752
author Lee, Kyunghoon
Park, Hyung-Doo
Kang, Eun-Suk
author_facet Lee, Kyunghoon
Park, Hyung-Doo
Kang, Eun-Suk
author_sort Lee, Kyunghoon
collection PubMed
description BACKGROUND: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV infection and reduction of false positive rate. METHODS: Four seroconversion panels were included. The third-generation ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay (Siemens Healthcare Diagnostics Inc., USA) and fourth-generation CHIV assay were used to test each panel for HIV infection. The presence of antigen was confirmed using HIV p24 antigen assay. To evaluate false-positivity and specificity, 54 HIV false-positive and HIV-negative serum samples from 100 hospitalized patients and 600 healthy subjects were included. RESULTS: Compared to the EHIV assay, the CHIV assay had a shorter window for three of the seroconversion panels: a difference of 10 days and two bleeds in one panel, and 4 days and one bleed in the other two panels. Only 34 of the 54 (63%) samples known to yield false-positive results by EHIV assay had repeatedly yielded reactive results in the CHIV assay. One of the 600 healthy subjects had a false-positive result with the CHIV assay; thus, the specificity was 99.85% (699/700). CHIV accurately determined the reactive results for the HIV-confirmed serum samples from known HIV patients and Korea Food & Drug Administration (KFDA) panels. CONCLUSIONS: The new fourth-generation ADVIA Centaur HIV assay is a sensitive and specific assay that shortens the serological window period and allows early diagnosis of HIV infection.
format Online
Article
Text
id pubmed-3819441
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-38194412013-11-07 Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay Lee, Kyunghoon Park, Hyung-Doo Kang, Eun-Suk Ann Lab Med Original Article BACKGROUND: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV infection and reduction of false positive rate. METHODS: Four seroconversion panels were included. The third-generation ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay (Siemens Healthcare Diagnostics Inc., USA) and fourth-generation CHIV assay were used to test each panel for HIV infection. The presence of antigen was confirmed using HIV p24 antigen assay. To evaluate false-positivity and specificity, 54 HIV false-positive and HIV-negative serum samples from 100 hospitalized patients and 600 healthy subjects were included. RESULTS: Compared to the EHIV assay, the CHIV assay had a shorter window for three of the seroconversion panels: a difference of 10 days and two bleeds in one panel, and 4 days and one bleed in the other two panels. Only 34 of the 54 (63%) samples known to yield false-positive results by EHIV assay had repeatedly yielded reactive results in the CHIV assay. One of the 600 healthy subjects had a false-positive result with the CHIV assay; thus, the specificity was 99.85% (699/700). CHIV accurately determined the reactive results for the HIV-confirmed serum samples from known HIV patients and Korea Food & Drug Administration (KFDA) panels. CONCLUSIONS: The new fourth-generation ADVIA Centaur HIV assay is a sensitive and specific assay that shortens the serological window period and allows early diagnosis of HIV infection. The Korean Society for Laboratory Medicine 2013-11 2013-10-17 /pmc/articles/PMC3819441/ /pubmed/24205491 http://dx.doi.org/10.3343/alm.2013.33.6.420 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Kyunghoon
Park, Hyung-Doo
Kang, Eun-Suk
Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title_full Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title_fullStr Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title_full_unstemmed Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title_short Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
title_sort reduction of the hiv seroconversion window period and false positive rate by using advia centaur hiv antigen/antibody combo assay
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819441/
https://www.ncbi.nlm.nih.gov/pubmed/24205491
http://dx.doi.org/10.3343/alm.2013.33.6.420
work_keys_str_mv AT leekyunghoon reductionofthehivseroconversionwindowperiodandfalsepositiveratebyusingadviacentaurhivantigenantibodycomboassay
AT parkhyungdoo reductionofthehivseroconversionwindowperiodandfalsepositiveratebyusingadviacentaurhivantigenantibodycomboassay
AT kangeunsuk reductionofthehivseroconversionwindowperiodandfalsepositiveratebyusingadviacentaurhivantigenantibodycomboassay