Cargando…
Spectral Asymmetry and Higuchi's Fractal Dimension Measures of Depression Electroencephalogram
This study was aimed to compare two electroencephalogram (EEG) analysis methods, spectral asymmetry index (SASI) and Higuchi's fractal dimension (HFD), for detection of depression. Linear SASI method is based on evaluation of the balance of powers in two EEG frequency bands in one channel selec...
Autores principales: | Bachmann, Maie, Lass, Jaanus, Suhhova, Anna, Hinrikus, Hiie |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3819823/ https://www.ncbi.nlm.nih.gov/pubmed/24232245 http://dx.doi.org/10.1155/2013/251638 |
Ejemplares similares
-
Higuchi Fractal Properties of Onset Epilepsy Electroencephalogram
por: Khoa, Truong Quang Dang, et al.
Publicado: (2012) -
Negative Correlation Between Functional Connectivity and Small-Worldness in the Alpha Frequency Band of a Healthy Brain
por: Päeske, Laura, et al.
Publicado: (2020) -
Correlation between electroencephalographic markers in the healthy brain
por: Päeske, Laura, et al.
Publicado: (2023) -
Methods of electroencephalographic signal analysis for detection of small hidden changes
por: Hinrikus, Hiie, et al.
Publicado: (2007) -
Higuchi’s fractal dimension, but not frontal or posterior alpha asymmetry, predicts PID-5 anxiousness more than depressivity
por: Kawe, Tame N. J., et al.
Publicado: (2019)