Cargando…

Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions

. [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 pati...

Descripción completa

Detalles Bibliográficos
Autor principal: Kim, Yong-Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3820174/
https://www.ncbi.nlm.nih.gov/pubmed/24259775
http://dx.doi.org/10.1589/jpts.25.1279
_version_ 1782290094759084032
author Kim, Yong-Wook
author_facet Kim, Yong-Wook
author_sort Kim, Yong-Wook
collection PubMed
description . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test–retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test–retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95–0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = −0.77– −0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity.
format Online
Article
Text
id pubmed-3820174
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-38201742013-11-20 Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions Kim, Yong-Wook J Phys Ther Sci Original . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test–retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test–retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95–0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = −0.77– −0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity. The Society of Physical Therapy Science 2013-11-20 2013-10 /pmc/articles/PMC3820174/ /pubmed/24259775 http://dx.doi.org/10.1589/jpts.25.1279 Text en 2013©by the Society of Physical Therapy Science http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original
Kim, Yong-Wook
Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title_full Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title_fullStr Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title_full_unstemmed Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title_short Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions
title_sort clinical usefulness of the pendulum test using a nk table to measure the spasticity of patients with brain lesions
topic Original
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3820174/
https://www.ncbi.nlm.nih.gov/pubmed/24259775
http://dx.doi.org/10.1589/jpts.25.1279
work_keys_str_mv AT kimyongwook clinicalusefulnessofthependulumtestusinganktabletomeasurethespasticityofpatientswithbrainlesions