The Closed Circuit And The Low Flow Systems
A breathing system is defined as an assembly of components, which delivers gases from the anesthesia machine to the patients’ airways. When the components are arranged as a circle, it is termed a circle system. The flow of exhaled gases is unidirectional in the system. The system contains a componen...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3821269/ https://www.ncbi.nlm.nih.gov/pubmed/24249885 http://dx.doi.org/10.4103/0019-5049.120149 |
_version_ | 1782290272197017600 |
---|---|
author | Parthasarathy, S |
author_facet | Parthasarathy, S |
author_sort | Parthasarathy, S |
collection | PubMed |
description | A breathing system is defined as an assembly of components, which delivers gases from the anesthesia machine to the patients’ airways. When the components are arranged as a circle, it is termed a circle system. The flow of exhaled gases is unidirectional in the system. The system contains a component (absorber), which absorbs exhaled carbon dioxide and it is not necessary to give high fresh gas flows as in Mapleson systems. When the adjustable pressure limiting (APL) valve is closed and all the exhaled gases without carbon dioxide are returned to the patient, the system becomes a totally closed one. Such a circle system can be used with flows as low as 250 to 500 mL and clinically can be termed as low-flow systems. The components of the circle system can be arranged in different ways with adherence to basic rules: (1) Unidirectional valve must be present between the reservoir bag and the patient on both inspiratory and expiratory sides; (2) fresh gas must not enter the system between the expiratory unidirectional valve and the patient; and (3) the APL valve must not be placed between the patient and the inspiratory unidirectional valve. The functional analysis is explained in detail. During the function, the arrangement of components is significant only at higher fresh gas flows. With the introduction of low resistance valves, improved soda lime canisters and low dead space connectors, the use of less complicated pediatric circle systems is gaining popularity to anesthetize children. There are bidirectional flow systems with carbon dioxide absorption. The Waters to and fro system, a classic example of bidirectional flow systems with a canister to absorb carbon dioxide, is valveless and portable. It was widely used in the past and now is only of historical importance. |
format | Online Article Text |
id | pubmed-3821269 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-38212692013-11-18 The Closed Circuit And The Low Flow Systems Parthasarathy, S Indian J Anaesth Review Article A breathing system is defined as an assembly of components, which delivers gases from the anesthesia machine to the patients’ airways. When the components are arranged as a circle, it is termed a circle system. The flow of exhaled gases is unidirectional in the system. The system contains a component (absorber), which absorbs exhaled carbon dioxide and it is not necessary to give high fresh gas flows as in Mapleson systems. When the adjustable pressure limiting (APL) valve is closed and all the exhaled gases without carbon dioxide are returned to the patient, the system becomes a totally closed one. Such a circle system can be used with flows as low as 250 to 500 mL and clinically can be termed as low-flow systems. The components of the circle system can be arranged in different ways with adherence to basic rules: (1) Unidirectional valve must be present between the reservoir bag and the patient on both inspiratory and expiratory sides; (2) fresh gas must not enter the system between the expiratory unidirectional valve and the patient; and (3) the APL valve must not be placed between the patient and the inspiratory unidirectional valve. The functional analysis is explained in detail. During the function, the arrangement of components is significant only at higher fresh gas flows. With the introduction of low resistance valves, improved soda lime canisters and low dead space connectors, the use of less complicated pediatric circle systems is gaining popularity to anesthetize children. There are bidirectional flow systems with carbon dioxide absorption. The Waters to and fro system, a classic example of bidirectional flow systems with a canister to absorb carbon dioxide, is valveless and portable. It was widely used in the past and now is only of historical importance. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3821269/ /pubmed/24249885 http://dx.doi.org/10.4103/0019-5049.120149 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Parthasarathy, S The Closed Circuit And The Low Flow Systems |
title | The Closed Circuit And The Low Flow Systems |
title_full | The Closed Circuit And The Low Flow Systems |
title_fullStr | The Closed Circuit And The Low Flow Systems |
title_full_unstemmed | The Closed Circuit And The Low Flow Systems |
title_short | The Closed Circuit And The Low Flow Systems |
title_sort | closed circuit and the low flow systems |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3821269/ https://www.ncbi.nlm.nih.gov/pubmed/24249885 http://dx.doi.org/10.4103/0019-5049.120149 |
work_keys_str_mv | AT parthasarathys theclosedcircuitandthelowflowsystems AT parthasarathys closedcircuitandthelowflowsystems |