Cargando…

A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach

Active magnetic bearings (AMBs) have become a key technology in various industrial applications. Self-sensing AMBs provide an integrated sensorless solution for position estimation, consolidating the sensing and actuating functions into a single electromagnetic transducer. The approach aims to reduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Niemann, Andries C., van Schoor, George, du Rand, Carel P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3821321/
https://www.ncbi.nlm.nih.gov/pubmed/24030681
http://dx.doi.org/10.3390/s130912149
_version_ 1782290283726110720
author Niemann, Andries C.
van Schoor, George
du Rand, Carel P.
author_facet Niemann, Andries C.
van Schoor, George
du Rand, Carel P.
author_sort Niemann, Andries C.
collection PubMed
description Active magnetic bearings (AMBs) have become a key technology in various industrial applications. Self-sensing AMBs provide an integrated sensorless solution for position estimation, consolidating the sensing and actuating functions into a single electromagnetic transducer. The approach aims to reduce possible hardware failure points, production costs, and system complexity. Despite these advantages, self-sensing methods must address various technical challenges to maximize the performance thereof. This paper presents the direct current measurement (DCM) approach for self-sensing AMBs, denoting the direct measurement of the current ripple component. In AMB systems, switching power amplifiers (PAs) modulate the rotor position information onto the current waveform. Demodulation self-sensing techniques then use bandpass and lowpass filters to estimate the rotor position from the voltage and current signals. However, the additional phase-shift introduced by these filters results in lower stability margins. The DCM approach utilizes a novel PA switching method that directly measures the current ripple to obtain duty-cycle invariant position estimates. Demodulation filters are largely excluded to minimize additional phase-shift in the position estimates. Basic functionality and performance of the proposed self-sensing approach are demonstrated via a transient simulation model as well as a high current (10 A) experimental system. A digital implementation of amplitude modulation self-sensing serves as a comparative estimator.
format Online
Article
Text
id pubmed-3821321
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-38213212013-11-09 A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach Niemann, Andries C. van Schoor, George du Rand, Carel P. Sensors (Basel) Article Active magnetic bearings (AMBs) have become a key technology in various industrial applications. Self-sensing AMBs provide an integrated sensorless solution for position estimation, consolidating the sensing and actuating functions into a single electromagnetic transducer. The approach aims to reduce possible hardware failure points, production costs, and system complexity. Despite these advantages, self-sensing methods must address various technical challenges to maximize the performance thereof. This paper presents the direct current measurement (DCM) approach for self-sensing AMBs, denoting the direct measurement of the current ripple component. In AMB systems, switching power amplifiers (PAs) modulate the rotor position information onto the current waveform. Demodulation self-sensing techniques then use bandpass and lowpass filters to estimate the rotor position from the voltage and current signals. However, the additional phase-shift introduced by these filters results in lower stability margins. The DCM approach utilizes a novel PA switching method that directly measures the current ripple to obtain duty-cycle invariant position estimates. Demodulation filters are largely excluded to minimize additional phase-shift in the position estimates. Basic functionality and performance of the proposed self-sensing approach are demonstrated via a transient simulation model as well as a high current (10 A) experimental system. A digital implementation of amplitude modulation self-sensing serves as a comparative estimator. MDPI 2013-09-11 /pmc/articles/PMC3821321/ /pubmed/24030681 http://dx.doi.org/10.3390/s130912149 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Niemann, Andries C.
van Schoor, George
du Rand, Carel P.
A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title_full A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title_fullStr A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title_full_unstemmed A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title_short A Self-Sensing Active Magnetic Bearing Based on a Direct Current Measurement Approach
title_sort self-sensing active magnetic bearing based on a direct current measurement approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3821321/
https://www.ncbi.nlm.nih.gov/pubmed/24030681
http://dx.doi.org/10.3390/s130912149
work_keys_str_mv AT niemannandriesc aselfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach
AT vanschoorgeorge aselfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach
AT durandcarelp aselfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach
AT niemannandriesc selfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach
AT vanschoorgeorge selfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach
AT durandcarelp selfsensingactivemagneticbearingbasedonadirectcurrentmeasurementapproach