Cargando…

Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor

BACKGROUND: Deep brain stimulation (DBS) of the thalamus is a safe and efficient method for treatment of disabling tremor in patient with essential tremor (ET). However, successful tremor suppression after surgery requires careful selection of stimulus parameters. Our aim was to examine the possible...

Descripción completa

Detalles Bibliográficos
Autores principales: Wastensson, Gunilla, Holmberg, Björn, Johnels, Bo, Barregard, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Columbia University Libraries/Information Services 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3822146/
https://www.ncbi.nlm.nih.gov/pubmed/24255800
_version_ 1782290389185593344
author Wastensson, Gunilla
Holmberg, Björn
Johnels, Bo
Barregard, Lars
author_facet Wastensson, Gunilla
Holmberg, Björn
Johnels, Bo
Barregard, Lars
author_sort Wastensson, Gunilla
collection PubMed
description BACKGROUND: Deep brain stimulation (DBS) of the thalamus is a safe and efficient method for treatment of disabling tremor in patient with essential tremor (ET). However, successful tremor suppression after surgery requires careful selection of stimulus parameters. Our aim was to examine the possible use of certain quantitative methods for evaluating the efficacy of thalamic DBS in ET patients in clinical practice, and to compare these methods with traditional clinical tests. METHODS: We examined 22 patients using the Essential Tremor Rating Scale (ETRS) and quantitative assessment of tremor with the stimulator both activated and deactivated. We used an accelerometer (CATSYS tremor Pen) for quantitative measurement of postural tremor, and a eurythmokinesimeter (EKM) to evaluate kinetic tremor in a rapid pointing task. RESULTS: The efficacy of DBS on tremor suppression was prominent irrespective of the method used. The agreement between clinical rating of postural tremor and tremor intensity as measured by the CATSYS tremor pen was relatively high (r(s) = 0.74). The agreement between kinetic tremor as assessed by the ETRS and the main outcome variable from the EKM test was low (r(s) = 0.34). The lack of agreement indicates that the EKM test is not comparable with the clinical test. DISCUSSION: Quantitative methods, such as the CATSYS tremor pen, could be a useful complement to clinical tremor assessment in evaluating the efficacy of DBS in clinical practice. Future studies should evaluate the precision of these methods and long-term impact on tremor suppression, activities of daily living (ADL) function and quality of life.
format Online
Article
Text
id pubmed-3822146
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Columbia University Libraries/Information Services
record_format MEDLINE/PubMed
spelling pubmed-38221462013-11-19 Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor Wastensson, Gunilla Holmberg, Björn Johnels, Bo Barregard, Lars Tremor Other Hyperkinet Mov (N Y) Articles BACKGROUND: Deep brain stimulation (DBS) of the thalamus is a safe and efficient method for treatment of disabling tremor in patient with essential tremor (ET). However, successful tremor suppression after surgery requires careful selection of stimulus parameters. Our aim was to examine the possible use of certain quantitative methods for evaluating the efficacy of thalamic DBS in ET patients in clinical practice, and to compare these methods with traditional clinical tests. METHODS: We examined 22 patients using the Essential Tremor Rating Scale (ETRS) and quantitative assessment of tremor with the stimulator both activated and deactivated. We used an accelerometer (CATSYS tremor Pen) for quantitative measurement of postural tremor, and a eurythmokinesimeter (EKM) to evaluate kinetic tremor in a rapid pointing task. RESULTS: The efficacy of DBS on tremor suppression was prominent irrespective of the method used. The agreement between clinical rating of postural tremor and tremor intensity as measured by the CATSYS tremor pen was relatively high (r(s) = 0.74). The agreement between kinetic tremor as assessed by the ETRS and the main outcome variable from the EKM test was low (r(s) = 0.34). The lack of agreement indicates that the EKM test is not comparable with the clinical test. DISCUSSION: Quantitative methods, such as the CATSYS tremor pen, could be a useful complement to clinical tremor assessment in evaluating the efficacy of DBS in clinical practice. Future studies should evaluate the precision of these methods and long-term impact on tremor suppression, activities of daily living (ADL) function and quality of life. Columbia University Libraries/Information Services 2013-11-04 /pmc/articles/PMC3822146/ /pubmed/24255800 Text en http://creativecommons.org/licenses/by-nc-nd/3.0/us/ This is an open-access article distributed under the terms of the Creative Commons Attribution–Noncommerical–No Derivatives License, which permits the user to copy, distribute, and transmit the work provided that the original author and source are credited; that no commercial use is made of the work; and that the work is not altered or transformed.
spellingShingle Articles
Wastensson, Gunilla
Holmberg, Björn
Johnels, Bo
Barregard, Lars
Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title_full Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title_fullStr Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title_full_unstemmed Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title_short Quantitative Methods for Evaluating the Efficacy of Thalamic Deep Brain Stimulation in Patients with Essential Tremor
title_sort quantitative methods for evaluating the efficacy of thalamic deep brain stimulation in patients with essential tremor
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3822146/
https://www.ncbi.nlm.nih.gov/pubmed/24255800
work_keys_str_mv AT wastenssongunilla quantitativemethodsforevaluatingtheefficacyofthalamicdeepbrainstimulationinpatientswithessentialtremor
AT holmbergbjorn quantitativemethodsforevaluatingtheefficacyofthalamicdeepbrainstimulationinpatientswithessentialtremor
AT johnelsbo quantitativemethodsforevaluatingtheefficacyofthalamicdeepbrainstimulationinpatientswithessentialtremor
AT barregardlars quantitativemethodsforevaluatingtheefficacyofthalamicdeepbrainstimulationinpatientswithessentialtremor