Cargando…
Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom
We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3823780/ https://www.ncbi.nlm.nih.gov/pubmed/23685667 http://dx.doi.org/10.1093/jrr/rrt059 |
_version_ | 1782290611942981632 |
---|---|
author | Tanooka, Masao Doi, Hiroshi Miura, Hideharu Inoue, Hiroyuki Niwa, Yasue Takada, Yasuhiro Fujiwara, Masayuki Sakai, Toshiyuki Sakamoto, Kiyoshi Kamikonya, Norihiko Hirota, Shozo |
author_facet | Tanooka, Masao Doi, Hiroshi Miura, Hideharu Inoue, Hiroyuki Niwa, Yasue Takada, Yasuhiro Fujiwara, Masayuki Sakai, Toshiyuki Sakamoto, Kiyoshi Kamikonya, Norihiko Hirota, Shozo |
author_sort | Tanooka, Masao |
collection | PubMed |
description | We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic film. The film holder has two parallel walls whose facing inner surfaces are equipped with spiral grooves in a mirrored configuration. The film is inserted into the spiral grooves by its side edges and runs along them to be positioned on a spiral plane. Dose calculation was performed by applying clinical VMAT plans to the spiral water phantom using a commercial Monte Carlo-based treatment-planning system, Monaco, whereas dose was measured by delivering the VMAT beams to the phantom. The calculated dose distributions were resampled on the spiral plane, and the dose distributions recorded on the film were scanned. Comparisons between the calculated and measured dose distributions yielded an average gamma-index pass rate of 87.0% (range, 91.2–84.6%) in nine prostate VMAT plans under 3 mm/3% criteria with a dose-calculation grid size of 2 mm. The pass rates were increased beyond 90% (average, 91.1%; range, 90.1–92.0%) when the dose-calculation grid size was decreased to 1 mm. We have confirmed that 3D radiochromic film dosimetry using the spiral water phantom is a simple and cost-effective approach to VMAT dose verification. |
format | Online Article Text |
id | pubmed-3823780 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-38237802013-11-12 Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom Tanooka, Masao Doi, Hiroshi Miura, Hideharu Inoue, Hiroyuki Niwa, Yasue Takada, Yasuhiro Fujiwara, Masayuki Sakai, Toshiyuki Sakamoto, Kiyoshi Kamikonya, Norihiko Hirota, Shozo J Radiat Res Technology We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic film. The film holder has two parallel walls whose facing inner surfaces are equipped with spiral grooves in a mirrored configuration. The film is inserted into the spiral grooves by its side edges and runs along them to be positioned on a spiral plane. Dose calculation was performed by applying clinical VMAT plans to the spiral water phantom using a commercial Monte Carlo-based treatment-planning system, Monaco, whereas dose was measured by delivering the VMAT beams to the phantom. The calculated dose distributions were resampled on the spiral plane, and the dose distributions recorded on the film were scanned. Comparisons between the calculated and measured dose distributions yielded an average gamma-index pass rate of 87.0% (range, 91.2–84.6%) in nine prostate VMAT plans under 3 mm/3% criteria with a dose-calculation grid size of 2 mm. The pass rates were increased beyond 90% (average, 91.1%; range, 90.1–92.0%) when the dose-calculation grid size was decreased to 1 mm. We have confirmed that 3D radiochromic film dosimetry using the spiral water phantom is a simple and cost-effective approach to VMAT dose verification. Oxford University Press 2013-11 2013-05-17 /pmc/articles/PMC3823780/ /pubmed/23685667 http://dx.doi.org/10.1093/jrr/rrt059 Text en © The Author 2013. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technology Tanooka, Masao Doi, Hiroshi Miura, Hideharu Inoue, Hiroyuki Niwa, Yasue Takada, Yasuhiro Fujiwara, Masayuki Sakai, Toshiyuki Sakamoto, Kiyoshi Kamikonya, Norihiko Hirota, Shozo Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title | Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title_full | Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title_fullStr | Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title_full_unstemmed | Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title_short | Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
title_sort | three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3823780/ https://www.ncbi.nlm.nih.gov/pubmed/23685667 http://dx.doi.org/10.1093/jrr/rrt059 |
work_keys_str_mv | AT tanookamasao threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT doihiroshi threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT miurahideharu threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT inouehiroyuki threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT niwayasue threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT takadayasuhiro threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT fujiwaramasayuki threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT sakaitoshiyuki threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT sakamotokiyoshi threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT kamikonyanorihiko threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom AT hirotashozo threedimensionalradiochromicfilmdosimetryforvolumetricmodulatedarctherapyusingaspiralwaterphantom |