Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer
The development of jet nebulizers for medical purposes is an important challenge of aerosol therapy. The performance of a nebulizer is characterized by its output rate of droplets with a diameter under 5 µm. However the optimization of this parameter through experiments has reached a plateau. The pu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3823843/ https://www.ncbi.nlm.nih.gov/pubmed/24244334 http://dx.doi.org/10.1371/journal.pone.0078659 |
_version_ | 1782290619963539456 |
---|---|
author | Lelong, Nicolas Vecellio, Laurent Sommer de Gélicourt, Yann Tanguy, Christian Diot, Patrice Junqua-Moullet, Alexandra |
author_facet | Lelong, Nicolas Vecellio, Laurent Sommer de Gélicourt, Yann Tanguy, Christian Diot, Patrice Junqua-Moullet, Alexandra |
author_sort | Lelong, Nicolas |
collection | PubMed |
description | The development of jet nebulizers for medical purposes is an important challenge of aerosol therapy. The performance of a nebulizer is characterized by its output rate of droplets with a diameter under 5 µm. However the optimization of this parameter through experiments has reached a plateau. The purpose of this study is to design a numerical model simulating the nebulization process and to compare it with experimental data. Such a model could provide a better understanding of the atomization process and the parameters influencing the nebulizer output. A model based on the Updraft nebulizer (Hudson) was designed with ANSYS Workbench. Boundary conditions were set with experimental data then transient 3D calculations were run on a 4 µm mesh with ANSYS Fluent. Two air flow rate (2 L/min and 8 L/min, limits of the operating range) were considered to account for different turbulence regimes. Numerical and experimental results were compared according to phenomenology and droplet size. The behavior of the liquid was compared to images acquired through shadowgraphy with a CCD Camera. Three experimental methods, laser diffractometry, phase Doppler anemometry (PDA) and shadowgraphy were used to characterize the droplet size distributions. Camera images showed similar patterns as numerical results. Droplet sizes obtained numerically are overestimated in relation to PDA and diffractometry, which only consider spherical droplets. However, at both flow rates, size distributions extracted from numerical image processing were similar to distributions obtained from shadowgraphy image processing. The simulation then provides a good understanding and prediction of the phenomena involved in the fragmentation of droplets over 10 µm. The laws of dynamics apply to droplets down to 1 µm, so we can assume the continuity of the distribution and extrapolate the results for droplets between 1 and 10 µm. So, this model could help predicting nebulizer output with defined geometrical and physical parameters. |
format | Online Article Text |
id | pubmed-3823843 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38238432013-11-15 Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer Lelong, Nicolas Vecellio, Laurent Sommer de Gélicourt, Yann Tanguy, Christian Diot, Patrice Junqua-Moullet, Alexandra PLoS One Research Article The development of jet nebulizers for medical purposes is an important challenge of aerosol therapy. The performance of a nebulizer is characterized by its output rate of droplets with a diameter under 5 µm. However the optimization of this parameter through experiments has reached a plateau. The purpose of this study is to design a numerical model simulating the nebulization process and to compare it with experimental data. Such a model could provide a better understanding of the atomization process and the parameters influencing the nebulizer output. A model based on the Updraft nebulizer (Hudson) was designed with ANSYS Workbench. Boundary conditions were set with experimental data then transient 3D calculations were run on a 4 µm mesh with ANSYS Fluent. Two air flow rate (2 L/min and 8 L/min, limits of the operating range) were considered to account for different turbulence regimes. Numerical and experimental results were compared according to phenomenology and droplet size. The behavior of the liquid was compared to images acquired through shadowgraphy with a CCD Camera. Three experimental methods, laser diffractometry, phase Doppler anemometry (PDA) and shadowgraphy were used to characterize the droplet size distributions. Camera images showed similar patterns as numerical results. Droplet sizes obtained numerically are overestimated in relation to PDA and diffractometry, which only consider spherical droplets. However, at both flow rates, size distributions extracted from numerical image processing were similar to distributions obtained from shadowgraphy image processing. The simulation then provides a good understanding and prediction of the phenomena involved in the fragmentation of droplets over 10 µm. The laws of dynamics apply to droplets down to 1 µm, so we can assume the continuity of the distribution and extrapolate the results for droplets between 1 and 10 µm. So, this model could help predicting nebulizer output with defined geometrical and physical parameters. Public Library of Science 2013-11-11 /pmc/articles/PMC3823843/ /pubmed/24244334 http://dx.doi.org/10.1371/journal.pone.0078659 Text en © 2013 Lelong et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Lelong, Nicolas Vecellio, Laurent Sommer de Gélicourt, Yann Tanguy, Christian Diot, Patrice Junqua-Moullet, Alexandra Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title | Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title_full | Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title_fullStr | Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title_full_unstemmed | Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title_short | Comparison of Numerical Simulations to Experiments for Atomization in a Jet Nebulizer |
title_sort | comparison of numerical simulations to experiments for atomization in a jet nebulizer |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3823843/ https://www.ncbi.nlm.nih.gov/pubmed/24244334 http://dx.doi.org/10.1371/journal.pone.0078659 |
work_keys_str_mv | AT lelongnicolas comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer AT vecelliolaurent comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer AT sommerdegelicourtyann comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer AT tanguychristian comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer AT diotpatrice comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer AT junquamoulletalexandra comparisonofnumericalsimulationstoexperimentsforatomizationinajetnebulizer |