Cargando…
The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of eac...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Periodontology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3825989/ https://www.ncbi.nlm.nih.gov/pubmed/24236244 http://dx.doi.org/10.5051/jpis.2013.43.5.221 |
_version_ | 1782290860586565632 |
---|---|
author | Mahshid, Minoo Saboury, Aboulfazl Sadr, Seyed Jalil Fayyaz, Ali Kadkhodazadeh, Mahdi |
author_facet | Mahshid, Minoo Saboury, Aboulfazl Sadr, Seyed Jalil Fayyaz, Ali Kadkhodazadeh, Mahdi |
author_sort | Mahshid, Minoo |
collection | PubMed |
description | PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). RESULTS: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. CONCLUSION: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs. |
format | Online Article Text |
id | pubmed-3825989 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Korean Academy of Periodontology |
record_format | MEDLINE/PubMed |
spelling | pubmed-38259892013-11-14 The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices Mahshid, Minoo Saboury, Aboulfazl Sadr, Seyed Jalil Fayyaz, Ali Kadkhodazadeh, Mahdi J Periodontal Implant Sci Research Article PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). RESULTS: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. CONCLUSION: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs. Korean Academy of Periodontology 2013-10 2013-10-29 /pmc/articles/PMC3825989/ /pubmed/24236244 http://dx.doi.org/10.5051/jpis.2013.43.5.221 Text en Copyright © 2013 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/). |
spellingShingle | Research Article Mahshid, Minoo Saboury, Aboulfazl Sadr, Seyed Jalil Fayyaz, Ali Kadkhodazadeh, Mahdi The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title | The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title_full | The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title_fullStr | The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title_full_unstemmed | The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title_short | The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
title_sort | combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3825989/ https://www.ncbi.nlm.nih.gov/pubmed/24236244 http://dx.doi.org/10.5051/jpis.2013.43.5.221 |
work_keys_str_mv | AT mahshidminoo thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT sabouryaboulfazl thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT sadrseyedjalil thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT fayyazali thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT kadkhodazadehmahdi thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT mahshidminoo combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT sabouryaboulfazl combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT sadrseyedjalil combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT fayyazali combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices AT kadkhodazadehmahdi combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices |