Cargando…

The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices

PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of eac...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahshid, Minoo, Saboury, Aboulfazl, Sadr, Seyed Jalil, Fayyaz, Ali, Kadkhodazadeh, Mahdi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3825989/
https://www.ncbi.nlm.nih.gov/pubmed/24236244
http://dx.doi.org/10.5051/jpis.2013.43.5.221
_version_ 1782290860586565632
author Mahshid, Minoo
Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayyaz, Ali
Kadkhodazadeh, Mahdi
author_facet Mahshid, Minoo
Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayyaz, Ali
Kadkhodazadeh, Mahdi
author_sort Mahshid, Minoo
collection PubMed
description PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). RESULTS: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. CONCLUSION: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs.
format Online
Article
Text
id pubmed-3825989
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-38259892013-11-14 The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices Mahshid, Minoo Saboury, Aboulfazl Sadr, Seyed Jalil Fayyaz, Ali Kadkhodazadeh, Mahdi J Periodontal Implant Sci Research Article PURPOSE: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (±10% of the target torque) of spring-style mechanical torque devices (S-S MTDs). METHODS: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). RESULTS: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. CONCLUSION: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs. Korean Academy of Periodontology 2013-10 2013-10-29 /pmc/articles/PMC3825989/ /pubmed/24236244 http://dx.doi.org/10.5051/jpis.2013.43.5.221 Text en Copyright © 2013 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Mahshid, Minoo
Saboury, Aboulfazl
Sadr, Seyed Jalil
Fayyaz, Ali
Kadkhodazadeh, Mahdi
The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title_full The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title_fullStr The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title_full_unstemmed The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title_short The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
title_sort combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3825989/
https://www.ncbi.nlm.nih.gov/pubmed/24236244
http://dx.doi.org/10.5051/jpis.2013.43.5.221
work_keys_str_mv AT mahshidminoo thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT sabouryaboulfazl thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT sadrseyedjalil thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT fayyazali thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT kadkhodazadehmahdi thecombinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT mahshidminoo combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT sabouryaboulfazl combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT sadrseyedjalil combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT fayyazali combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices
AT kadkhodazadehmahdi combinedeffectofdismantlingforsteamsterilizationandagingontheaccuracyofspringstylemechanicaltorquedevices