Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging

The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) tech...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Ye, Yu, Baiying, Pang, Yong, Vigneron, Daniel B., Zhang, Xiaoliang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3827179/
https://www.ncbi.nlm.nih.gov/pubmed/24265823
http://dx.doi.org/10.1371/journal.pone.0080428
_version_ 1782291021847068672
author Li, Ye
Yu, Baiying
Pang, Yong
Vigneron, Daniel B.
Zhang, Xiaoliang
author_facet Li, Ye
Yu, Baiying
Pang, Yong
Vigneron, Daniel B.
Zhang, Xiaoliang
author_sort Li, Ye
collection PubMed
description The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR signal excitation and detection and to investigate its performance for MR imaging, particularly, at ultrahigh magnetic fields. A prototype resonator based on CMDM method implemented by using microstrip transmission line was designed and fabricated for 7T imaging. Both the common mode (CM) and the differential mode (DM) of the resonator were tuned and matched at 298MHz independently. Numerical electromagnetic simulation was performed to verify the orthogonal B(1) field direction of the two modes of the CMDM resonator. Both workbench tests and MR imaging experiments were carried out to evaluate the performance. The intrinsic decoupling between the two modes of the CMDM resonator was demonstrated by the bench test, showing a better than -36 dB transmission coefficient between the two modes at resonance frequency. The MR images acquired by using each mode and the images combined in quadrature showed that the CM and DM of the proposed resonator provided similar B(1) coverage and achieved SNR improvement in the entire region of interest. The simulation and experimental results demonstrate that the proposed CMDM method with distributed-element transmission line technique is a feasible and efficient technique for planar quadrature RF coil design at ultrahigh fields, providing intrinsic decoupling between two quadrature channels and high frequency capability. Due to its simple and compact geometry and easy implementation of decoupling methods, the CMDM quadrature resonator can possibly be a good candidate for design blocks in multichannel RF coil arrays.
format Online
Article
Text
id pubmed-3827179
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38271792013-11-21 Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging Li, Ye Yu, Baiying Pang, Yong Vigneron, Daniel B. Zhang, Xiaoliang PLoS One Research Article The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR signal excitation and detection and to investigate its performance for MR imaging, particularly, at ultrahigh magnetic fields. A prototype resonator based on CMDM method implemented by using microstrip transmission line was designed and fabricated for 7T imaging. Both the common mode (CM) and the differential mode (DM) of the resonator were tuned and matched at 298MHz independently. Numerical electromagnetic simulation was performed to verify the orthogonal B(1) field direction of the two modes of the CMDM resonator. Both workbench tests and MR imaging experiments were carried out to evaluate the performance. The intrinsic decoupling between the two modes of the CMDM resonator was demonstrated by the bench test, showing a better than -36 dB transmission coefficient between the two modes at resonance frequency. The MR images acquired by using each mode and the images combined in quadrature showed that the CM and DM of the proposed resonator provided similar B(1) coverage and achieved SNR improvement in the entire region of interest. The simulation and experimental results demonstrate that the proposed CMDM method with distributed-element transmission line technique is a feasible and efficient technique for planar quadrature RF coil design at ultrahigh fields, providing intrinsic decoupling between two quadrature channels and high frequency capability. Due to its simple and compact geometry and easy implementation of decoupling methods, the CMDM quadrature resonator can possibly be a good candidate for design blocks in multichannel RF coil arrays. Public Library of Science 2013-11-12 /pmc/articles/PMC3827179/ /pubmed/24265823 http://dx.doi.org/10.1371/journal.pone.0080428 Text en © 2013 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Li, Ye
Yu, Baiying
Pang, Yong
Vigneron, Daniel B.
Zhang, Xiaoliang
Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title_full Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title_fullStr Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title_full_unstemmed Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title_short Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
title_sort planar quadrature rf transceiver design using common-mode differential-mode (cmdm) transmission line method for 7t mr imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3827179/
https://www.ncbi.nlm.nih.gov/pubmed/24265823
http://dx.doi.org/10.1371/journal.pone.0080428
work_keys_str_mv AT liye planarquadraturerftransceiverdesignusingcommonmodedifferentialmodecmdmtransmissionlinemethodfor7tmrimaging
AT yubaiying planarquadraturerftransceiverdesignusingcommonmodedifferentialmodecmdmtransmissionlinemethodfor7tmrimaging
AT pangyong planarquadraturerftransceiverdesignusingcommonmodedifferentialmodecmdmtransmissionlinemethodfor7tmrimaging
AT vignerondanielb planarquadraturerftransceiverdesignusingcommonmodedifferentialmodecmdmtransmissionlinemethodfor7tmrimaging
AT zhangxiaoliang planarquadraturerftransceiverdesignusingcommonmodedifferentialmodecmdmtransmissionlinemethodfor7tmrimaging