Cargando…
Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC(
Determination of drug residues in food is of great importance due to their toxicity. Long-term exposure with low level of drug residues could be important, especially in children. Based on document study, oxytetracycline )OTC) is a prophylaxis and treatment agent for great number of diseases and pos...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3828913/ https://www.ncbi.nlm.nih.gov/pubmed/24250346 |
_version_ | 1782291308142919680 |
---|---|
author | Khosrokhavar, Roya Hosseini, Mir-Jamal Shoeibi, Shahram Jannat, Behrooz |
author_facet | Khosrokhavar, Roya Hosseini, Mir-Jamal Shoeibi, Shahram Jannat, Behrooz |
author_sort | Khosrokhavar, Roya |
collection | PubMed |
description | Determination of drug residues in food is of great importance due to their toxicity. Long-term exposure with low level of drug residues could be important, especially in children. Based on document study, oxytetracycline )OTC) is a prophylaxis and treatment agent for great number of diseases and possesses a broad spectrum activity against many pathogenic organisms and can be toxic or cause allergic reactions in some hypersensitive individual’s if the residues of drug exist in the infant formula. The previous studies show that using high-performance liquid chromatography (HPLC) is useful for OTC detection in milk. Therefore, we decided to measure OTC in infant formula. The purpose of this study was to investigate residual OTC in consuming infant formula using HPLC. The limit of quantification (LOQ) was 51 ng/mL. This result showed that the samples had no residues of OTC in infant formula from different companies. |
format | Online Article Text |
id | pubmed-3828913 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-38289132013-11-18 Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( Khosrokhavar, Roya Hosseini, Mir-Jamal Shoeibi, Shahram Jannat, Behrooz Iran J Pharm Res Original Article Determination of drug residues in food is of great importance due to their toxicity. Long-term exposure with low level of drug residues could be important, especially in children. Based on document study, oxytetracycline )OTC) is a prophylaxis and treatment agent for great number of diseases and possesses a broad spectrum activity against many pathogenic organisms and can be toxic or cause allergic reactions in some hypersensitive individual’s if the residues of drug exist in the infant formula. The previous studies show that using high-performance liquid chromatography (HPLC) is useful for OTC detection in milk. Therefore, we decided to measure OTC in infant formula. The purpose of this study was to investigate residual OTC in consuming infant formula using HPLC. The limit of quantification (LOQ) was 51 ng/mL. This result showed that the samples had no residues of OTC in infant formula from different companies. Shaheed Beheshti University of Medical Sciences 2011 /pmc/articles/PMC3828913/ /pubmed/24250346 Text en © 2011 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Khosrokhavar, Roya Hosseini, Mir-Jamal Shoeibi, Shahram Jannat, Behrooz Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title | Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title_full | Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title_fullStr | Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title_full_unstemmed | Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title_short | Detection of Oxytetracycline Residuein Infant Formulaby High-Performance Liquid Chromatography)HPLC( |
title_sort | detection of oxytetracycline residuein infant formulaby high-performance liquid chromatography)hplc( |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3828913/ https://www.ncbi.nlm.nih.gov/pubmed/24250346 |
work_keys_str_mv | AT khosrokhavarroya detectionofoxytetracyclineresidueininfantformulabyhighperformanceliquidchromatographyhplc AT hosseinimirjamal detectionofoxytetracyclineresidueininfantformulabyhighperformanceliquidchromatographyhplc AT shoeibishahram detectionofoxytetracyclineresidueininfantformulabyhighperformanceliquidchromatographyhplc AT jannatbehrooz detectionofoxytetracyclineresidueininfantformulabyhighperformanceliquidchromatographyhplc |