Cargando…

Balloon Occlusive Diameter of Non-Circular Atrial Septal Defects in Transcatheter Closure with Amplatzer Septal Occluder

BACKGROUND AND OBJECTIVES: The aim of this study was to investigate the balloon occlusive diameter (BOD) of non-circular defects in the transcatheter closure of atrial septal defect (ASD). SUBJECTS AND METHODS: A total of 67 patients who had undergone transcatheter closure of an ASD were reviewed re...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kwang Hoon, Song, Jinyoung, Kang, I-Seok, Chang, Sung-A, Huh, June, Park, Seung Woo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3831014/
https://www.ncbi.nlm.nih.gov/pubmed/24255652
http://dx.doi.org/10.4070/kcj.2013.43.10.681
Descripción
Sumario:BACKGROUND AND OBJECTIVES: The aim of this study was to investigate the balloon occlusive diameter (BOD) of non-circular defects in the transcatheter closure of atrial septal defect (ASD). SUBJECTS AND METHODS: A total of 67 patients who had undergone transcatheter closure of an ASD were reviewed retrospectively. A non-circular defect was defined as the ratio of the short diameter to the long diameter of the defect on the en-face image less than 0.75. The BOD was compared with the long diameter of the defect and then compared between the two groups. RESULTS: There were 22 patients with circular defects and 45 patients with non-circular defects. The difference in BOD measuring from the long diameter of the defect was quite different between the two groups and significantly smaller in non-circular morphology (0.1±4.0 vs. 2.3±2.1, p=0.006). The difference in BOD measurement from the long diameter of ASD showed a positive correlation with the ratio of the short diameter to the long diameter of ASD (b/a) (r(2)=0.102, p=0.008). In the non-circular morphology of ASD, the difference in BOD measured from the long diameter had a significant negative correlation with the long diameter of ASD (r(2)=0.230, p=0.001), whereas in circular ASD, no significant correlation was found between the difference in BOD and the long diameter of ASD (p=0.201). CONCLUSION: The BOD compared with the long diameter measured from three-dimensional transesophageal echocardiography was smaller in non-circular ASD than in circular ASD. This difference was much smaller in non-circular ASD with a large long diameter.