Assessing radiotracer kinetics in the Langendorff perfused heart
BACKGROUND: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data ana...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3831261/ https://www.ncbi.nlm.nih.gov/pubmed/24225195 http://dx.doi.org/10.1186/2191-219X-3-74 |
_version_ | 1782291583302893568 |
---|---|
author | Mariotti, Erika Veronese, Mattia Dunn, Joel T Medina, Rodolfo A Blower, Philip J Southworth, Richard Eykyn, Thomas R |
author_facet | Mariotti, Erika Veronese, Mattia Dunn, Joel T Medina, Rodolfo A Blower, Philip J Southworth, Richard Eykyn, Thomas R |
author_sort | Mariotti, Erika |
collection | PubMed |
description | BACKGROUND: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data analysis to the characterisation of PET tracer kinetics applied to Langendorff perfused hearts. METHODS: Monte Carlo simulations were used to study the accuracy and reproducibility of linear and non-linear spectral analysis (SA/NLSA), the Patlak graphical method and normalised tissue activity (NA). The methods were used to analyse time-activity curves of two widely used PET tracers, [(18) F]-FDG and [(18) F]-FMISO, acquired ex vivo from Langendorff perfused rat hearts under normoxic and hypoxic conditions. RESULTS: Monte Carlo simulations showed NLSA to be superior to SA in identifying and quantifying the presence of irreversible trapping component (α(o)), for low values of α(o). The performance of NLSA and SA for high values of trapping was comparable. NLSA was also more precise than SA in determining the absence of trapping over the range of simulated kinetics and SNR. Simulations also suggest that the semi-quantitative method NA is adequate for the evaluation of trapping, and it was found to be more accurate than Patlak. The values of α(0) estimated with NLSA from the time series of both [(18) F]-FDG and [(18) F]-FMISO increased significantly from normoxia to hypoxia in agreement with previous studies. The values of trapping derived using SA increased but not significantly, reflecting the larger error associate with this method. Patlak estimated from the experimental datasets increased from normoxia to hypoxia but was not significant. NA estimated from the [(18) F]-FDG data increased from normoxia to hypoxia, but was not significant, whilst NA calculated for [(18) F]-FMISO time-activity curves increased significantly. CONCLUSIONS: Monte Carlo simulations suggested that spectral-based quantitative analysis methods are adequate for the kinetic characterisation of time-activity curves acquired ex vivo from perfused hearts. The uptake rate Patlak and the index NA also represent a good alternative to the SA and NLSA algorithms when the aim of the kinetic analysis is to measure changes in the amount of tracer trapped in the irreversible compartment in response to external stimuli. For low levels of trapping, NLSA and NA were subject to lower errors than SA and Patlak, respectively. |
format | Online Article Text |
id | pubmed-3831261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Springer |
record_format | MEDLINE/PubMed |
spelling | pubmed-38312612013-11-20 Assessing radiotracer kinetics in the Langendorff perfused heart Mariotti, Erika Veronese, Mattia Dunn, Joel T Medina, Rodolfo A Blower, Philip J Southworth, Richard Eykyn, Thomas R EJNMMI Res Original Research BACKGROUND: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data analysis to the characterisation of PET tracer kinetics applied to Langendorff perfused hearts. METHODS: Monte Carlo simulations were used to study the accuracy and reproducibility of linear and non-linear spectral analysis (SA/NLSA), the Patlak graphical method and normalised tissue activity (NA). The methods were used to analyse time-activity curves of two widely used PET tracers, [(18) F]-FDG and [(18) F]-FMISO, acquired ex vivo from Langendorff perfused rat hearts under normoxic and hypoxic conditions. RESULTS: Monte Carlo simulations showed NLSA to be superior to SA in identifying and quantifying the presence of irreversible trapping component (α(o)), for low values of α(o). The performance of NLSA and SA for high values of trapping was comparable. NLSA was also more precise than SA in determining the absence of trapping over the range of simulated kinetics and SNR. Simulations also suggest that the semi-quantitative method NA is adequate for the evaluation of trapping, and it was found to be more accurate than Patlak. The values of α(0) estimated with NLSA from the time series of both [(18) F]-FDG and [(18) F]-FMISO increased significantly from normoxia to hypoxia in agreement with previous studies. The values of trapping derived using SA increased but not significantly, reflecting the larger error associate with this method. Patlak estimated from the experimental datasets increased from normoxia to hypoxia but was not significant. NA estimated from the [(18) F]-FDG data increased from normoxia to hypoxia, but was not significant, whilst NA calculated for [(18) F]-FMISO time-activity curves increased significantly. CONCLUSIONS: Monte Carlo simulations suggested that spectral-based quantitative analysis methods are adequate for the kinetic characterisation of time-activity curves acquired ex vivo from perfused hearts. The uptake rate Patlak and the index NA also represent a good alternative to the SA and NLSA algorithms when the aim of the kinetic analysis is to measure changes in the amount of tracer trapped in the irreversible compartment in response to external stimuli. For low levels of trapping, NLSA and NA were subject to lower errors than SA and Patlak, respectively. Springer 2013-11-14 /pmc/articles/PMC3831261/ /pubmed/24225195 http://dx.doi.org/10.1186/2191-219X-3-74 Text en Copyright © 2013 Mariotti et al.; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Mariotti, Erika Veronese, Mattia Dunn, Joel T Medina, Rodolfo A Blower, Philip J Southworth, Richard Eykyn, Thomas R Assessing radiotracer kinetics in the Langendorff perfused heart |
title | Assessing radiotracer kinetics in the Langendorff perfused heart |
title_full | Assessing radiotracer kinetics in the Langendorff perfused heart |
title_fullStr | Assessing radiotracer kinetics in the Langendorff perfused heart |
title_full_unstemmed | Assessing radiotracer kinetics in the Langendorff perfused heart |
title_short | Assessing radiotracer kinetics in the Langendorff perfused heart |
title_sort | assessing radiotracer kinetics in the langendorff perfused heart |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3831261/ https://www.ncbi.nlm.nih.gov/pubmed/24225195 http://dx.doi.org/10.1186/2191-219X-3-74 |
work_keys_str_mv | AT mariottierika assessingradiotracerkineticsinthelangendorffperfusedheart AT veronesemattia assessingradiotracerkineticsinthelangendorffperfusedheart AT dunnjoelt assessingradiotracerkineticsinthelangendorffperfusedheart AT medinarodolfoa assessingradiotracerkineticsinthelangendorffperfusedheart AT blowerphilipj assessingradiotracerkineticsinthelangendorffperfusedheart AT southworthrichard assessingradiotracerkineticsinthelangendorffperfusedheart AT eykynthomasr assessingradiotracerkineticsinthelangendorffperfusedheart |