Cargando…

Transthoracic measurement of left coronary artery flow reserve improves the diagnostic value of routine dipyridamole-atropine stress echocardiogram

INTRODUCTION: We hypothesized that coronary flow reserve (CFR) in the left anterior descending artery (LAD) can be effectively measured during an accelerated dipyridamole-atropine stress echocardiography (DASE) protocol to improve the diagnostic performance of the test. MATERIAL AND METHODS: In 64 p...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasprzak, Jarosław D., Wejner-Mik, Paulina, Nouri, Aria, Szymczyk, Ewa, Krzemińska-Pakuła, Maria, Lipiec, Piotr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3832825/
https://www.ncbi.nlm.nih.gov/pubmed/24273560
http://dx.doi.org/10.5114/aoms.2013.38673
Descripción
Sumario:INTRODUCTION: We hypothesized that coronary flow reserve (CFR) in the left anterior descending artery (LAD) can be effectively measured during an accelerated dipyridamole-atropine stress echocardiography (DASE) protocol to improve the diagnostic performance of the test. MATERIAL AND METHODS: In 64 patients with suspected or known coronary artery disease scheduled for coronary angiography DASE with concomitant CFR measurement in LAD was performed. RESULTS: Coronary flow reserve measurement and calculation were feasible in 83% of patients. The positive predictive value of undetectable LAD flow was 81% for severe LAD disease. Measured values of CFR were in the range 1.3–4.1 (mean: 2.2 ±0.7). Significantly lower CFR was found in patients with LAD disease (1.97 ±0.62 vs. 2.55 ±0.57, p = 0.0015). The optimal cutoff for detecting ≥ 50% stenosis was CFR ≤ 2.1 (ROC AUC 0.776), corresponding with 68% sensitivity and 84% specificity. In patients with negative DASE results 67% of patients with LAD disease had abnormal CFR, whereas in patients with a positive DASE result 92% of patients with normal LAD had normal CFR. The DASE diagnostic accuracy for the detection of coronary artery disease (CAD) increased from 75% to 85% when CFR measurement was added to wall motion abnormality (WMA) analysis. No test with both abnormalities was false positive for the detection of coronary disease. CONCLUSIONS: Incorporation of CFR measurement into WMA-based stress echocardiography is feasible even in an accelerated DASE protocol and can be translated into an approximate gain of 10% in overall test accuracy.