Cost-effectiveness of sentinel lymph node biopsy vs inguinofemoral lymphadenectomy in women with vulval cancer

BACKGROUND: This study examines the cost-effectiveness of sentinel lymph node biopsy, a potentially less morbid procedure, compared with inguinofemoral lymphadenectomy (IFL) among women with stage I and stage II vulval squamous cell carcinoma. METHODS: A model-based economic evaluation was undertake...

Descripción completa

Detalles Bibliográficos
Autores principales: Sutton, A J, Barton, P, Sundar, S, Meads, C, Rosenthal, A N, Baldwin, P, Khan, K, Roberts, T E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3833218/
https://www.ncbi.nlm.nih.gov/pubmed/24129233
http://dx.doi.org/10.1038/bjc.2013.631
Descripción
Sumario:BACKGROUND: This study examines the cost-effectiveness of sentinel lymph node biopsy, a potentially less morbid procedure, compared with inguinofemoral lymphadenectomy (IFL) among women with stage I and stage II vulval squamous cell carcinoma. METHODS: A model-based economic evaluation was undertaken based on clinical evidence from a systematic review of published sources. A decision tree model was developed with the structure being informed by clinical input, taking the perspective of the health-care provider. RESULTS: For overall survival for 2 years, IFL was found to be the most cost-effective option and dominated all other strategies, being the least costly and most effective. For morbidity-free related outcomes for 2 years, sentinel lymph node (SLN) biopsy with 99mTc and blue dye and haematoxylin & eosin (H&E) histopathology, with ultrastaging and immunohistochemistry reserved for those that test negative following H&E is likely to be the most effective approach. CONCLUSION: SLN biopsy using 99mTc and blue dye with ultrastaging may be considered the most cost-effective strategy based on the outcome of survival free of morbidity for 2 years. The findings here also indicate that using blue dye and H&E for the identification of the SLN and the identification of metastasis, respectively, are not sensitive enough to be used on their own.