High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()

Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there i...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Shaoxia, McMullan, Greg, Faruqi, Abdul R., Murshudov, Garib N., Short, Judith M., Scheres, Sjors H.W., Henderson, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3834153/
https://www.ncbi.nlm.nih.gov/pubmed/23872039
http://dx.doi.org/10.1016/j.ultramic.2013.06.004
_version_ 1782291938932686848
author Chen, Shaoxia
McMullan, Greg
Faruqi, Abdul R.
Murshudov, Garib N.
Short, Judith M.
Scheres, Sjors H.W.
Henderson, Richard
author_facet Chen, Shaoxia
McMullan, Greg
Faruqi, Abdul R.
Murshudov, Garib N.
Short, Judith M.
Scheres, Sjors H.W.
Henderson, Richard
author_sort Chen, Shaoxia
collection PubMed
description Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there is much more noise than signal at high resolution in the images, this creates the possibility of noise reinforcement in the 3D map, which can give a false impression of the resolution attained. The balance between signal and noise in the final map at its limiting resolution depends on the image processing procedure and is not easily predicted. There is a growing awareness in the cryoEM community of how to avoid such over-fitting and over-estimation of resolution. Equally, there has been a reluctance to use the two principal methods of avoidance because they give lower resolution estimates, which some people believe are too pessimistic. Here we describe a simple test that is compatible with any image processing protocol. The test allows measurement of the amount of signal and the amount of noise from overfitting that is present in the final 3D map. We have applied the method to two different sets of cryoEM images of the enzyme beta-galactosidase using several image processing packages. Our procedure involves substituting the Fourier components of the initial particle image stack beyond a chosen resolution by either the Fourier components from an adjacent area of background, or by simple randomisation of the phases of the particle structure factors. This substituted noise thus has the same spectral power distribution as the original data. Comparison of the Fourier Shell Correlation (FSC) plots from the 3D map obtained using the experimental data with that from the same data with high-resolution noise (HR-noise) substituted allows an unambiguous measurement of the amount of overfitting and an accompanying resolution assessment. A simple formula can be used to calculate an unbiased FSC from the two curves, even when a substantial amount of overfitting is present. The approach is software independent. The user is therefore completely free to use any established method or novel combination of methods, provided the HR-noise test is carried out in parallel. Applying this procedure to cryoEM images of beta-galactosidase shows how overfitting varies greatly depending on the procedure, but in the best case shows no overfitting and a resolution of ~6 Å. (382 words)
format Online
Article
Text
id pubmed-3834153
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-38341532013-12-01 High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy() Chen, Shaoxia McMullan, Greg Faruqi, Abdul R. Murshudov, Garib N. Short, Judith M. Scheres, Sjors H.W. Henderson, Richard Ultramicroscopy Article Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there is much more noise than signal at high resolution in the images, this creates the possibility of noise reinforcement in the 3D map, which can give a false impression of the resolution attained. The balance between signal and noise in the final map at its limiting resolution depends on the image processing procedure and is not easily predicted. There is a growing awareness in the cryoEM community of how to avoid such over-fitting and over-estimation of resolution. Equally, there has been a reluctance to use the two principal methods of avoidance because they give lower resolution estimates, which some people believe are too pessimistic. Here we describe a simple test that is compatible with any image processing protocol. The test allows measurement of the amount of signal and the amount of noise from overfitting that is present in the final 3D map. We have applied the method to two different sets of cryoEM images of the enzyme beta-galactosidase using several image processing packages. Our procedure involves substituting the Fourier components of the initial particle image stack beyond a chosen resolution by either the Fourier components from an adjacent area of background, or by simple randomisation of the phases of the particle structure factors. This substituted noise thus has the same spectral power distribution as the original data. Comparison of the Fourier Shell Correlation (FSC) plots from the 3D map obtained using the experimental data with that from the same data with high-resolution noise (HR-noise) substituted allows an unambiguous measurement of the amount of overfitting and an accompanying resolution assessment. A simple formula can be used to calculate an unbiased FSC from the two curves, even when a substantial amount of overfitting is present. The approach is software independent. The user is therefore completely free to use any established method or novel combination of methods, provided the HR-noise test is carried out in parallel. Applying this procedure to cryoEM images of beta-galactosidase shows how overfitting varies greatly depending on the procedure, but in the best case shows no overfitting and a resolution of ~6 Å. (382 words) Elsevier 2013-12 /pmc/articles/PMC3834153/ /pubmed/23872039 http://dx.doi.org/10.1016/j.ultramic.2013.06.004 Text en © 2013 The Authors https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
Chen, Shaoxia
McMullan, Greg
Faruqi, Abdul R.
Murshudov, Garib N.
Short, Judith M.
Scheres, Sjors H.W.
Henderson, Richard
High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title_full High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title_fullStr High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title_full_unstemmed High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title_short High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy()
title_sort high-resolution noise substitution to measure overfitting and validate resolution in 3d structure determination by single particle electron cryomicroscopy()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3834153/
https://www.ncbi.nlm.nih.gov/pubmed/23872039
http://dx.doi.org/10.1016/j.ultramic.2013.06.004
work_keys_str_mv AT chenshaoxia highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT mcmullangreg highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT faruqiabdulr highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT murshudovgaribn highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT shortjudithm highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT scheressjorshw highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy
AT hendersonrichard highresolutionnoisesubstitutiontomeasureoverfittingandvalidateresolutionin3dstructuredeterminationbysingleparticleelectroncryomicroscopy