Cargando…
Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataract
Seventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior cap...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3835205/ https://www.ncbi.nlm.nih.gov/pubmed/24303209 http://dx.doi.org/10.1155/2013/921646 |
Sumario: | Seventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior capsular flap is created with cystotome. The capsular flap is vacuumed with a 25-gauge visco elastic's cannula, which connected to the phaco machine vacuum. The continuous circular capsulorhexis (CCC) is completed with the using bimanual irrigation and aspiration system of phaco machine. Vacuum-assisted CCC technique was used in 78 cases of uncomplicated immature senile cataracts. All cases were done under sub-Tenon's anesthesia. A complete CCC was achieved in all cases. Performing CCC with our technique is easy, safe, and cheap. It may be an alternative method to CCC by using OVD and forceps. |
---|