Cargando…

Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners

Cerebral blood flow (CBF) in the human primary visual cortex is correlated with the loss of visual function in neuro-ophthalmological diseases. Advanced three-dimensional pseudo-continuous arterial spin labeling (3D pCASL), as a non-invasive method to access the CBF, can be a novel measurement to de...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Diandian, Wu, Bing, Shi, Kaining, Ma, Lin, Cai, Youquan, Lou, Xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3835829/
https://www.ncbi.nlm.nih.gov/pubmed/24278137
http://dx.doi.org/10.1371/journal.pone.0079471
_version_ 1782292213813739520
author Huang, Diandian
Wu, Bing
Shi, Kaining
Ma, Lin
Cai, Youquan
Lou, Xin
author_facet Huang, Diandian
Wu, Bing
Shi, Kaining
Ma, Lin
Cai, Youquan
Lou, Xin
author_sort Huang, Diandian
collection PubMed
description Cerebral blood flow (CBF) in the human primary visual cortex is correlated with the loss of visual function in neuro-ophthalmological diseases. Advanced three-dimensional pseudo-continuous arterial spin labeling (3D pCASL), as a non-invasive method to access the CBF, can be a novel measurement to detect the visual cortex. The objective of the study was to assess the intra- and inter-scanner reliability of 3D pCASL of the visual cortex in healthy adults and suggest the selection of different post-labeling delay times (PLDs). For this reason, 3D pCASL was conducted in two 3.0T MR three times with twelve healthy volunteers at an interval of 10–15 days. The 1st and 3rd tests were performed on scanner-1, and the 2nd test was performed on scanner-2. The value of the CBF was abstracted from the visual cortex with two PLDs. The intra- and inter-scanner reliability and reproducibility were evaluated with the intraclass correlation coefficient (ICC) and Bland-Altman plots. By estimating the mean value of the CBF in the visual cortex, the intra-scanner results demonstrated the higher reliability (ICC for PLD = 1.5 second presented at 0.743 compared with 0.829 for PLD = 2.5 seconds), and the Bland-Altman plots showed the reproducibility at a longer PLD. We conclude that the calibrated 3D pCASL approach provides a highly reproducible measurement of the CBF of the visual cortex that can serve as a useful quantitative probe for research conducted at multiple centers and for the long-term observation of the clinical effects of neuro-opthalmological diseases.
format Online
Article
Text
id pubmed-3835829
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38358292013-11-25 Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners Huang, Diandian Wu, Bing Shi, Kaining Ma, Lin Cai, Youquan Lou, Xin PLoS One Research Article Cerebral blood flow (CBF) in the human primary visual cortex is correlated with the loss of visual function in neuro-ophthalmological diseases. Advanced three-dimensional pseudo-continuous arterial spin labeling (3D pCASL), as a non-invasive method to access the CBF, can be a novel measurement to detect the visual cortex. The objective of the study was to assess the intra- and inter-scanner reliability of 3D pCASL of the visual cortex in healthy adults and suggest the selection of different post-labeling delay times (PLDs). For this reason, 3D pCASL was conducted in two 3.0T MR three times with twelve healthy volunteers at an interval of 10–15 days. The 1st and 3rd tests were performed on scanner-1, and the 2nd test was performed on scanner-2. The value of the CBF was abstracted from the visual cortex with two PLDs. The intra- and inter-scanner reliability and reproducibility were evaluated with the intraclass correlation coefficient (ICC) and Bland-Altman plots. By estimating the mean value of the CBF in the visual cortex, the intra-scanner results demonstrated the higher reliability (ICC for PLD = 1.5 second presented at 0.743 compared with 0.829 for PLD = 2.5 seconds), and the Bland-Altman plots showed the reproducibility at a longer PLD. We conclude that the calibrated 3D pCASL approach provides a highly reproducible measurement of the CBF of the visual cortex that can serve as a useful quantitative probe for research conducted at multiple centers and for the long-term observation of the clinical effects of neuro-opthalmological diseases. Public Library of Science 2013-11-20 /pmc/articles/PMC3835829/ /pubmed/24278137 http://dx.doi.org/10.1371/journal.pone.0079471 Text en © 2013 Huang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Huang, Diandian
Wu, Bing
Shi, Kaining
Ma, Lin
Cai, Youquan
Lou, Xin
Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title_full Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title_fullStr Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title_full_unstemmed Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title_short Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
title_sort reliability of three-dimensional pseudo-continuous arterial spin labeling mr imaging for measuring visual cortex perfusion on two 3t scanners
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3835829/
https://www.ncbi.nlm.nih.gov/pubmed/24278137
http://dx.doi.org/10.1371/journal.pone.0079471
work_keys_str_mv AT huangdiandian reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners
AT wubing reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners
AT shikaining reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners
AT malin reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners
AT caiyouquan reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners
AT louxin reliabilityofthreedimensionalpseudocontinuousarterialspinlabelingmrimagingformeasuringvisualcortexperfusionontwo3tscanners