Cargando…

Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature

Study Design  Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is...

Descripción completa

Detalles Bibliográficos
Autores principales: Potter, Michael Q., Lawrence, Brandon D., Kinikini, Daniel V., Brodke, Darrel S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3836958/
https://www.ncbi.nlm.nih.gov/pubmed/24436714
http://dx.doi.org/10.1055/s-0033-1357358
Descripción
Sumario:Study Design  Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is retrospectively reviewed. The offending hardware was removed after gaining endovascular control of the aorta. Results Intraoperative aortography was normal and no graft was placed. The patient remains asymptomatic at 2 years after surgery. Conclusions Hardware impinging on the aorta can safely be removed by gaining endovascular control of the aorta. In the setting of normal intraoperative aortography in a young patient, we recommend against further intervention to avoid the known morbidity of aortic grafting.