Cargando…
Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature
Study Design Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3836958/ https://www.ncbi.nlm.nih.gov/pubmed/24436714 http://dx.doi.org/10.1055/s-0033-1357358 |
_version_ | 1782292375227334656 |
---|---|
author | Potter, Michael Q. Lawrence, Brandon D. Kinikini, Daniel V. Brodke, Darrel S. |
author_facet | Potter, Michael Q. Lawrence, Brandon D. Kinikini, Daniel V. Brodke, Darrel S. |
author_sort | Potter, Michael Q. |
collection | PubMed |
description | Study Design Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is retrospectively reviewed. The offending hardware was removed after gaining endovascular control of the aorta. Results Intraoperative aortography was normal and no graft was placed. The patient remains asymptomatic at 2 years after surgery. Conclusions Hardware impinging on the aorta can safely be removed by gaining endovascular control of the aorta. In the setting of normal intraoperative aortography in a young patient, we recommend against further intervention to avoid the known morbidity of aortic grafting. |
format | Online Article Text |
id | pubmed-3836958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-38369582014-10-01 Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature Potter, Michael Q. Lawrence, Brandon D. Kinikini, Daniel V. Brodke, Darrel S. Evid Based Spine Care J Article Study Design Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is retrospectively reviewed. The offending hardware was removed after gaining endovascular control of the aorta. Results Intraoperative aortography was normal and no graft was placed. The patient remains asymptomatic at 2 years after surgery. Conclusions Hardware impinging on the aorta can safely be removed by gaining endovascular control of the aorta. In the setting of normal intraoperative aortography in a young patient, we recommend against further intervention to avoid the known morbidity of aortic grafting. Georg Thieme Verlag KG 2013-10 /pmc/articles/PMC3836958/ /pubmed/24436714 http://dx.doi.org/10.1055/s-0033-1357358 Text en © Thieme Medical Publishers |
spellingShingle | Article Potter, Michael Q. Lawrence, Brandon D. Kinikini, Daniel V. Brodke, Darrel S. Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title | Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title_full | Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title_fullStr | Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title_full_unstemmed | Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title_short | Periaortic Pedicle Screw Removal with Endovascular Control of the Aorta and Intraoperative Aortography: A Case Report and Review of the Literature |
title_sort | periaortic pedicle screw removal with endovascular control of the aorta and intraoperative aortography: a case report and review of the literature |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3836958/ https://www.ncbi.nlm.nih.gov/pubmed/24436714 http://dx.doi.org/10.1055/s-0033-1357358 |
work_keys_str_mv | AT pottermichaelq periaorticpediclescrewremovalwithendovascularcontroloftheaortaandintraoperativeaortographyacasereportandreviewoftheliterature AT lawrencebrandond periaorticpediclescrewremovalwithendovascularcontroloftheaortaandintraoperativeaortographyacasereportandreviewoftheliterature AT kinikinidanielv periaorticpediclescrewremovalwithendovascularcontroloftheaortaandintraoperativeaortographyacasereportandreviewoftheliterature AT brodkedarrels periaorticpediclescrewremovalwithendovascularcontroloftheaortaandintraoperativeaortographyacasereportandreviewoftheliterature |