Cargando…

Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements

RATIONALE: Accurate measurement of subsolid pulmonary nodules (SSN) is becoming increasingly important in the management of these nodules. SSNs were previously quantified with time-consuming manual measurements. The aim of the present study is to test the feasibility of semi-automatic SSNs measureme...

Descripción completa

Detalles Bibliográficos
Autores principales: Scholten, Ernst Th., de Hoop, Bartjan, Jacobs, Colin, van Amelsvoort-van de Vorst, Saskia, van Klaveren, Rob J., Oudkerk, Matthijs, Vliegenthart, Rozemarijn, de Koning, Harry J., van der Aalst, Carlijn M., Mali, Willem Th M., Gietema, Hester A., Prokop, Mathias, van Ginneken, Bram, de Jong, Pim A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3837004/
https://www.ncbi.nlm.nih.gov/pubmed/24278264
http://dx.doi.org/10.1371/journal.pone.0080249
_version_ 1782292385499185152
author Scholten, Ernst Th.
de Hoop, Bartjan
Jacobs, Colin
van Amelsvoort-van de Vorst, Saskia
van Klaveren, Rob J.
Oudkerk, Matthijs
Vliegenthart, Rozemarijn
de Koning, Harry J.
van der Aalst, Carlijn M.
Mali, Willem Th M.
Gietema, Hester A.
Prokop, Mathias
van Ginneken, Bram
de Jong, Pim A.
author_facet Scholten, Ernst Th.
de Hoop, Bartjan
Jacobs, Colin
van Amelsvoort-van de Vorst, Saskia
van Klaveren, Rob J.
Oudkerk, Matthijs
Vliegenthart, Rozemarijn
de Koning, Harry J.
van der Aalst, Carlijn M.
Mali, Willem Th M.
Gietema, Hester A.
Prokop, Mathias
van Ginneken, Bram
de Jong, Pim A.
author_sort Scholten, Ernst Th.
collection PubMed
description RATIONALE: Accurate measurement of subsolid pulmonary nodules (SSN) is becoming increasingly important in the management of these nodules. SSNs were previously quantified with time-consuming manual measurements. The aim of the present study is to test the feasibility of semi-automatic SSNs measurements and to compare the results to the manual measurements. METHODS: In 33 lung cancer screening participants with 33 SSNs, the nodules were previously quantified by two observers manually. In the present study two observers quantified these nodules by using semi-automated nodule volumetry software. Nodules were quantified for effective diameter, volume and mass. The manual and semi-automatic measurements were compared using Bland-Altman plots and paired T tests. Observer agreement was calculated as an intraclass correlation coefficient. Data are presented as mean (SD). RESULTS: Semi-automated measurements were feasible in all 33 nodules. Nodule diameter, volume and mass were 11.2 (3.3) mm, 935 (691) ml and 379 (311) milligrams for observer 1 and 11.1 (3.7) mm, 986 (797) ml and 399 (344) milligrams for observer 2, respectively. Agreement between observers and within observer 1 for the semi-automatic measurements was good with an intraclass correlation coefficient >0.89. For observer 1 and observer 2, measured diameter was 8.8% and 10.3% larger (p<0.001), measured volume was 24.3% and 26.5% larger (p<0.001) and measured mass was 10.6% and 12.0% larger (p<0.001) with the semi-automatic program compared to the manual measurements. CONCLUSION: Semi-automated measurement of the diameter, volume and mass of SSNs is feasible with good observer agreement. Semi-automated measurement makes quantification of mass and volume feasible in daily practice.
format Online
Article
Text
id pubmed-3837004
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38370042013-11-25 Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements Scholten, Ernst Th. de Hoop, Bartjan Jacobs, Colin van Amelsvoort-van de Vorst, Saskia van Klaveren, Rob J. Oudkerk, Matthijs Vliegenthart, Rozemarijn de Koning, Harry J. van der Aalst, Carlijn M. Mali, Willem Th M. Gietema, Hester A. Prokop, Mathias van Ginneken, Bram de Jong, Pim A. PLoS One Research Article RATIONALE: Accurate measurement of subsolid pulmonary nodules (SSN) is becoming increasingly important in the management of these nodules. SSNs were previously quantified with time-consuming manual measurements. The aim of the present study is to test the feasibility of semi-automatic SSNs measurements and to compare the results to the manual measurements. METHODS: In 33 lung cancer screening participants with 33 SSNs, the nodules were previously quantified by two observers manually. In the present study two observers quantified these nodules by using semi-automated nodule volumetry software. Nodules were quantified for effective diameter, volume and mass. The manual and semi-automatic measurements were compared using Bland-Altman plots and paired T tests. Observer agreement was calculated as an intraclass correlation coefficient. Data are presented as mean (SD). RESULTS: Semi-automated measurements were feasible in all 33 nodules. Nodule diameter, volume and mass were 11.2 (3.3) mm, 935 (691) ml and 379 (311) milligrams for observer 1 and 11.1 (3.7) mm, 986 (797) ml and 399 (344) milligrams for observer 2, respectively. Agreement between observers and within observer 1 for the semi-automatic measurements was good with an intraclass correlation coefficient >0.89. For observer 1 and observer 2, measured diameter was 8.8% and 10.3% larger (p<0.001), measured volume was 24.3% and 26.5% larger (p<0.001) and measured mass was 10.6% and 12.0% larger (p<0.001) with the semi-automatic program compared to the manual measurements. CONCLUSION: Semi-automated measurement of the diameter, volume and mass of SSNs is feasible with good observer agreement. Semi-automated measurement makes quantification of mass and volume feasible in daily practice. Public Library of Science 2013-11-21 /pmc/articles/PMC3837004/ /pubmed/24278264 http://dx.doi.org/10.1371/journal.pone.0080249 Text en © 2013 Scholten et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Scholten, Ernst Th.
de Hoop, Bartjan
Jacobs, Colin
van Amelsvoort-van de Vorst, Saskia
van Klaveren, Rob J.
Oudkerk, Matthijs
Vliegenthart, Rozemarijn
de Koning, Harry J.
van der Aalst, Carlijn M.
Mali, Willem Th M.
Gietema, Hester A.
Prokop, Mathias
van Ginneken, Bram
de Jong, Pim A.
Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title_full Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title_fullStr Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title_full_unstemmed Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title_short Semi-Automatic Quantification of Subsolid Pulmonary Nodules: Comparison with Manual Measurements
title_sort semi-automatic quantification of subsolid pulmonary nodules: comparison with manual measurements
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3837004/
https://www.ncbi.nlm.nih.gov/pubmed/24278264
http://dx.doi.org/10.1371/journal.pone.0080249
work_keys_str_mv AT scholtenernstth semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT dehoopbartjan semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT jacobscolin semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT vanamelsvoortvandevorstsaskia semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT vanklaverenrobj semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT oudkerkmatthijs semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT vliegenthartrozemarijn semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT dekoningharryj semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT vanderaalstcarlijnm semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT maliwillemthm semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT gietemahestera semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT prokopmathias semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT vanginnekenbram semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements
AT dejongpima semiautomaticquantificationofsubsolidpulmonarynodulescomparisonwithmanualmeasurements