Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements

BACKGROUND: The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomograp...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanellopoulos, Anastasios John, Asimellis, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3838761/
https://www.ncbi.nlm.nih.gov/pubmed/24348011
http://dx.doi.org/10.2147/OPTH.S53718
_version_ 1782478378251583488
author Kanellopoulos, Anastasios John
Asimellis, George
author_facet Kanellopoulos, Anastasios John
Asimellis, George
author_sort Kanellopoulos, Anastasios John
collection PubMed
description BACKGROUND: The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS: Fifty eyes randomly selected from 50 patients were included in the study. Inclusion criteria were healthy, nonoperated eyes examined consecutively by the same examiner. Corneal imaging was performed by three different methods, ie, Oculyzer II, spectral-domain AS-OCT, and FH-UBM. Central corneal thickness measurements were compared using scatter diagrams, Bland-Altman plots (with bias and 95% confidence intervals), and two-paired analysis. RESULTS: The coefficient of determination (r(2)) between the Oculyzer II and AS-OCT measurements was 0.895. Likewise, the coefficient was 0.893 between the Oculyzer II and HF-UBM and 0.830 between the AS-OCT and HF-UBM. The trend line coefficients of linearity were 0.925 between the Oculyzer II and the AS-OCT, 1.006 between the Oculyzer II and HF-UBM, and 0.841 between the AS-OCT and HF-UBM. The differences in average corneal thickness between the three pairs of CCT measurements were −6.86 μm between the Oculyzer II and HF-UBM, −12.20 μm between the AS-OCT and Oculyzer II, and +19.06 μm between the HF-UBM and AS-OCT. CONCLUSION: The three methods used for corneal thickness measurement are highly correlated. Compared with the Scheimplug and ultrasound devices, the AS-OCT appears to report a more accurate, but overally thinner corneal pachymetry.
format Online
Article
Text
id pubmed-3838761
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-38387612013-12-13 Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements Kanellopoulos, Anastasios John Asimellis, George Clin Ophthalmol Original Research BACKGROUND: The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS: Fifty eyes randomly selected from 50 patients were included in the study. Inclusion criteria were healthy, nonoperated eyes examined consecutively by the same examiner. Corneal imaging was performed by three different methods, ie, Oculyzer II, spectral-domain AS-OCT, and FH-UBM. Central corneal thickness measurements were compared using scatter diagrams, Bland-Altman plots (with bias and 95% confidence intervals), and two-paired analysis. RESULTS: The coefficient of determination (r(2)) between the Oculyzer II and AS-OCT measurements was 0.895. Likewise, the coefficient was 0.893 between the Oculyzer II and HF-UBM and 0.830 between the AS-OCT and HF-UBM. The trend line coefficients of linearity were 0.925 between the Oculyzer II and the AS-OCT, 1.006 between the Oculyzer II and HF-UBM, and 0.841 between the AS-OCT and HF-UBM. The differences in average corneal thickness between the three pairs of CCT measurements were −6.86 μm between the Oculyzer II and HF-UBM, −12.20 μm between the AS-OCT and Oculyzer II, and +19.06 μm between the HF-UBM and AS-OCT. CONCLUSION: The three methods used for corneal thickness measurement are highly correlated. Compared with the Scheimplug and ultrasound devices, the AS-OCT appears to report a more accurate, but overally thinner corneal pachymetry. Dove Medical Press 2013 2013-11-20 /pmc/articles/PMC3838761/ /pubmed/24348011 http://dx.doi.org/10.2147/OPTH.S53718 Text en © 2013 Kanellopoulos and Asimellis. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Kanellopoulos, Anastasios John
Asimellis, George
Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title_full Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title_fullStr Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title_full_unstemmed Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title_short Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
title_sort comparison of high-resolution scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment oct corneal thickness measurements
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3838761/
https://www.ncbi.nlm.nih.gov/pubmed/24348011
http://dx.doi.org/10.2147/OPTH.S53718
work_keys_str_mv AT kanellopoulosanastasiosjohn comparisonofhighresolutionscheimpflugandhighfrequencyultrasoundbiomicroscopytoanteriorsegmentoctcornealthicknessmeasurements
AT asimellisgeorge comparisonofhighresolutionscheimpflugandhighfrequencyultrasoundbiomicroscopytoanteriorsegmentoctcornealthicknessmeasurements