Reproducibility of ambulatory blood pressure changes from the initial values on two different days

OBJECTIVE: We tested the reproducibility of changes in the ambulatory blood pressure (BP) from the initial values, an indicator of BP reactivity and cardiovascular health outcomes, in young, healthy adults. METHOD: The subjects wore an ambulatory BP monitor attached by the same investigator at the s...

Descripción completa

Detalles Bibliográficos
Autores principales: Ash, Garrett I., Walker, Timothy J., Olson, Kayla M., Stratton, Jeffrey H., Gómez, Ana L., Kraemer, William J., Volek, Jeff S., Pescatello, Linda S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3840371/
https://www.ncbi.nlm.nih.gov/pubmed/24473508
http://dx.doi.org/10.6061/clinics/2013(12)06
Descripción
Sumario:OBJECTIVE: We tested the reproducibility of changes in the ambulatory blood pressure (BP) from the initial values, an indicator of BP reactivity and cardiovascular health outcomes, in young, healthy adults. METHOD: The subjects wore an ambulatory BP monitor attached by the same investigator at the same time of day until the next morning on two different days (day 1 and day 2) separated by a week. We compared the ambulatory BP change from the initial values at hourly intervals over 24 waking and sleeping hours on days 1 and 2 using linear regression and repeated measures analysis of covariance. RESULTS: The subjects comprised 88 men and 57 women (mean age±SE 22.4±0.3 years) with normal BP (118.3±0.9/69.7±0.6 mmHg). For the total sample, the correlation between the ambulatory BP change on day 1 vs. day 2 over 24, waking, and sleeping hours ranged from 0.37–0.61; among women, the correlation was 0.38–0.71, and among men, it was 0.24–0.52. Among women, the ambulatory systolic/diastolic BP change was greater by 3.1±1.0/2.4±0.8 mmHg over 24 hours and by 3.0±1.1/2.4±0.8 mmHg over waking hours on day 1 than on day 2. The diastolic ambulatory BP change during sleeping hours was greater by 2.2±0.9 mmHg on day 1 than on day 2, but the systolic ambulatory BP change during sleeping hours on days 1 and 2 did not differ. Among men, the ambulatory BP change on days 1 and 2 did not differ. CONCLUSION: Our primary findings were that the ambulatory BP change from the initial values was moderately reproducible; however, it was more reproducible in men than in women. These results suggest that women, but not men, may experience an alerting reaction to initially wearing the ambulatory BP monitor.