Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies

Fouling of chromatographic resins over their operational lifetimes can be a significant problem for commercial bioseparations. In this article, scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column studies were applied to chara...

Descripción completa

Detalles Bibliográficos
Autores principales: Close, Edward J, Salm, Jeffrey R, Iskra, Timothy, Sørensen, Eva, Bracewell, Daniel G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3840701/
https://www.ncbi.nlm.nih.gov/pubmed/23483524
http://dx.doi.org/10.1002/bit.24898
_version_ 1782478554688126976
author Close, Edward J
Salm, Jeffrey R
Iskra, Timothy
Sørensen, Eva
Bracewell, Daniel G
author_facet Close, Edward J
Salm, Jeffrey R
Iskra, Timothy
Sørensen, Eva
Bracewell, Daniel G
author_sort Close, Edward J
collection PubMed
description Fouling of chromatographic resins over their operational lifetimes can be a significant problem for commercial bioseparations. In this article, scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column studies were applied to characterize a case study where fouling had been observed during process development. The fouling was found to occur on an anion exchange (AEX) polishing step following a protein A affinity capture step in a process for the purification of a monoclonal antibody. Fouled resin samples analyzed by SEM and batch uptake experiments indicated that after successive batch cycles, significant blockage of the pores at the resin surface occurred, thereby decreasing the protein uptake rate. Further studies were performed using CLSM to allow temporal and spatial measurements of protein adsorption within the resin, for clean, partially fouled and extensively fouled resin samples. These samples were packed within a miniaturized flowcell and challenged with fluorescently labeled albumin that enabled in situ measurements. The results indicated that the foulant has a significant impact on the kinetics of adsorption, severely decreasing the protein uptake rate, but only results in a minimal decrease in saturation capacity. The impact of the foulant on the kinetics of adsorption was further investigated by loading BSA onto fouled resin over an extended range of flow rates. By decreasing the flow rate during BSA loading, the capacity of the resin was recovered. These data support the hypothesis that the foulant is located on the particle surface, only penetrating the particle to a limited degree. The increased understanding into the nature of the fouling can help in the continued process development of this industrial example. Scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column experiments were applied to characterize a case study where fouling had been observed on an anion exchange chromatography in a monoclonal antibody process. The results suggest the foulant is located on the particle surface, resulting in a minimal decrease in saturation capacity, but having a significant impact on the kinetics of adsorption, severely decreasing protein uptake rate.
format Online
Article
Text
id pubmed-3840701
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-38407012013-12-02 Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies Close, Edward J Salm, Jeffrey R Iskra, Timothy Sørensen, Eva Bracewell, Daniel G Biotechnol Bioeng Articles Fouling of chromatographic resins over their operational lifetimes can be a significant problem for commercial bioseparations. In this article, scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column studies were applied to characterize a case study where fouling had been observed during process development. The fouling was found to occur on an anion exchange (AEX) polishing step following a protein A affinity capture step in a process for the purification of a monoclonal antibody. Fouled resin samples analyzed by SEM and batch uptake experiments indicated that after successive batch cycles, significant blockage of the pores at the resin surface occurred, thereby decreasing the protein uptake rate. Further studies were performed using CLSM to allow temporal and spatial measurements of protein adsorption within the resin, for clean, partially fouled and extensively fouled resin samples. These samples were packed within a miniaturized flowcell and challenged with fluorescently labeled albumin that enabled in situ measurements. The results indicated that the foulant has a significant impact on the kinetics of adsorption, severely decreasing the protein uptake rate, but only results in a minimal decrease in saturation capacity. The impact of the foulant on the kinetics of adsorption was further investigated by loading BSA onto fouled resin over an extended range of flow rates. By decreasing the flow rate during BSA loading, the capacity of the resin was recovered. These data support the hypothesis that the foulant is located on the particle surface, only penetrating the particle to a limited degree. The increased understanding into the nature of the fouling can help in the continued process development of this industrial example. Scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column experiments were applied to characterize a case study where fouling had been observed on an anion exchange chromatography in a monoclonal antibody process. The results suggest the foulant is located on the particle surface, resulting in a minimal decrease in saturation capacity, but having a significant impact on the kinetics of adsorption, severely decreasing protein uptake rate. Blackwell Publishing Ltd 2013-09 2013-03-31 /pmc/articles/PMC3840701/ /pubmed/23483524 http://dx.doi.org/10.1002/bit.24898 Text en Copyright © 2013 Wiley Periodicals, Inc. http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Articles
Close, Edward J
Salm, Jeffrey R
Iskra, Timothy
Sørensen, Eva
Bracewell, Daniel G
Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title_full Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title_fullStr Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title_full_unstemmed Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title_short Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies
title_sort fouling of an anion exchange chromatography operation in a monoclonal antibody process: visualization and kinetic studies
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3840701/
https://www.ncbi.nlm.nih.gov/pubmed/23483524
http://dx.doi.org/10.1002/bit.24898
work_keys_str_mv AT closeedwardj foulingofananionexchangechromatographyoperationinamonoclonalantibodyprocessvisualizationandkineticstudies
AT salmjeffreyr foulingofananionexchangechromatographyoperationinamonoclonalantibodyprocessvisualizationandkineticstudies
AT iskratimothy foulingofananionexchangechromatographyoperationinamonoclonalantibodyprocessvisualizationandkineticstudies
AT sørenseneva foulingofananionexchangechromatographyoperationinamonoclonalantibodyprocessvisualizationandkineticstudies
AT bracewelldanielg foulingofananionexchangechromatographyoperationinamonoclonalantibodyprocessvisualizationandkineticstudies