Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium

A new concept using a near-field thermometry sensor is presented, employing a tipless microcantilever experimentally validated for an aqueous medium within approximately one cantilever width from the solid interface. By correlating the thermal Brownian vibrating motion of the microcantilever with th...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Seonghwan, Kim, Kyung Chun, Kihm, Kenneth David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841887/
https://www.ncbi.nlm.nih.gov/pubmed/28903286
_version_ 1782292858751942656
author Kim, Seonghwan
Kim, Kyung Chun
Kihm, Kenneth David
author_facet Kim, Seonghwan
Kim, Kyung Chun
Kihm, Kenneth David
author_sort Kim, Seonghwan
collection PubMed
description A new concept using a near-field thermometry sensor is presented, employing a tipless microcantilever experimentally validated for an aqueous medium within approximately one cantilever width from the solid interface. By correlating the thermal Brownian vibrating motion of the microcantilever with the surrounding liquid temperature, the near-field microscale temperature distributions at the probing site are determined at separation distances of z = 5, 10, 20, and 40 μm while the microheater temperature is maintained at 50(°)C, 70(°)C, or 90(°)C. In addition, the near-field correction of the correlation is discussed to account for the quenched cantilever vibration frequencies, which are quenched due to the no-slip solid-wall interference. Higher thermal sensitivity and spatial resolution is expected when the vibration frequencies increase with a relatively short and thick cantilever and the dimensions of the microcantilever are reduced. Use of the microcantilever thermometry sensor can also reduce the complexity and mitigate the high cost associated with existing microfabricated thermocouples or thermoresistive sensors.
format Online
Article
Text
id pubmed-3841887
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-38418872013-11-29 Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium Kim, Seonghwan Kim, Kyung Chun Kihm, Kenneth David Sensors (Basel) Full Research Paper A new concept using a near-field thermometry sensor is presented, employing a tipless microcantilever experimentally validated for an aqueous medium within approximately one cantilever width from the solid interface. By correlating the thermal Brownian vibrating motion of the microcantilever with the surrounding liquid temperature, the near-field microscale temperature distributions at the probing site are determined at separation distances of z = 5, 10, 20, and 40 μm while the microheater temperature is maintained at 50(°)C, 70(°)C, or 90(°)C. In addition, the near-field correction of the correlation is discussed to account for the quenched cantilever vibration frequencies, which are quenched due to the no-slip solid-wall interference. Higher thermal sensitivity and spatial resolution is expected when the vibration frequencies increase with a relatively short and thick cantilever and the dimensions of the microcantilever are reduced. Use of the microcantilever thermometry sensor can also reduce the complexity and mitigate the high cost associated with existing microfabricated thermocouples or thermoresistive sensors. Molecular Diversity Preservation International (MDPI) 2007-12-06 /pmc/articles/PMC3841887/ /pubmed/28903286 Text en © 2007 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes.
spellingShingle Full Research Paper
Kim, Seonghwan
Kim, Kyung Chun
Kihm, Kenneth David
Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title_full Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title_fullStr Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title_full_unstemmed Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title_short Near-Field Thermometry Sensor Based on the Thermal Resonance of a Microcantilever in Aqueous Medium
title_sort near-field thermometry sensor based on the thermal resonance of a microcantilever in aqueous medium
topic Full Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841887/
https://www.ncbi.nlm.nih.gov/pubmed/28903286
work_keys_str_mv AT kimseonghwan nearfieldthermometrysensorbasedonthethermalresonanceofamicrocantileverinaqueousmedium
AT kimkyungchun nearfieldthermometrysensorbasedonthethermalresonanceofamicrocantileverinaqueousmedium
AT kihmkennethdavid nearfieldthermometrysensorbasedonthethermalresonanceofamicrocantileverinaqueousmedium